TruPortal Input Expansion Board Quick Reference

Status LEDs

Note the following details about Input Expansion board LEDs:

The VBUS yellow LED will flash on and off if there is no 
VBUS board communicating on the VBUS. If a VBUS board 
is present, the VBUS LED will remain off.

The green Power On LED stays on providing the operating 
voltage remains above 9.5 V. If the voltage is lower, the LED 
will flash on and off.

The two output LEDs follow when the outputs are active.

Serial Number Display

When the Input Expansion board is initially powered, the serial 
number is displayed in an encoded form. The number of times the 
VBUS yellow LED flashes while the green Processor OK LED 
stays on steady gives the digit value. 

For example, if the green LED is on and the yellow LED flashes 
three times, then the green LED goes off, the first digit is “3.” Then 
if the green LED turns back on and the yellow LED flashes nine 
times, then the green LED goes off, the second digit is “9,” etc.

“0” is indicated by the green LED turning on and the yellow LED 
not flashing. 

The entire serial number will be displayed, one digit at a time. It 
takes several seconds to complete the entire process. When the 
process is complete, the Processor OK green LED will flash on 
and off at a more moderate rate.

Specifications

The TP-ADD-IN-BRD is for use in low voltage, Class 2 circuits 
only. These specifications are subject to change without notice.

Power ratings 
-

Input: 12 VDC, 100 mA

-

Output: 12 VDC, 210 mA

Inputs: 16 inputs, standard EOL: 1k ohm in series, 1k ohm in 
parallel

Outputs: Two relay outputs 

Communication: SNAPP, VBUS

Cable requirements: 22 AWG (0.644 mm / 0.326 mm

2

), 

stranded
-

SNAPP bus: four conductors

-

VBUS: three conductors

-

Input wiring: two conductors

-

Power input: two conductors

Dimensions: 5.75 x 2.875 x 0.6 in. (146 x 73 x 15 mm)

Environmental
-

Temperature: +32 to +120° F (+0 to +49° C)

-

Humidity: 5—85% RHNC

-

BTU output: 4.1 BTU/hour

Certifications
-

UL294 Listed

-

FCC Part 15

-

CE marking

Regulatory Information

Contact Information

www.interlogix.com

Customer support: 

www.interlogix.com/support

© 25JUL13 United Technologies Corporation

Interlogix is part of UTC Climate Controls & Security, a unit of 
United Technologies Corporation.  All rights reserved.

Document number: 460803001C - July 2013

Manufacturer Interlogix 

Headquarters and Regulatory responsibility: 

Interlogix
3211 Progress Dr.
Lincolnton, NC 28092 USA 

EU authorized manufacturing representative: 

UTC Climate, Controls & Security B.V., 
Kelvinstraat 7, 6003 DH Weert, 
The Netherlands

Year of 
manufacture

The first two digits of the product serial number (located 
on the product identification label) are the year of 
manufacture.

North American 
standards

UL 294

FCC 
compliance

This device complies with part 15 of the FCC Rules. 
Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) 
this device must accept any interference received, 
including interference that may cause undesired 
operation.

Certification  

European Union 
directives

We declare under our sole responsibility that this product 
is in conformity with Directive 1999/5/EC (R&TTE), 2004/
108/EC (EMC), 2006/95/EC (LVD), and 93/68/EEC 
(Marking) based on test results using harmonized 
standards in accordance with the Directives mentioned.

Summary of Contents for TruPortal TP-ADD-IO-BRD

Page 1: ...system Packing List 16 input expansion board quantity 1 8 output relay expansion board quantity 1 Mounting plate depending on option ordered UL or CE enclosure with power supply depending on option ordered Installation kit which includes Two positional terminal plug in block quantity 2 Three positional terminal plug in block quantity 19 Four positional terminal plug in block quantity 1 End of line...

Page 2: ...anchors and mount the enclosure 4 The enclosure includes standard cable knockouts on each side including the back Use the proper size and type of cable strain reliefs to secure cables to the enclosure Figure 1 TP ADD IO enclosure Mounting the Module in the Enclosure One TP ADD IN BRD paired with exactly one TP ADD OUT BRD can be installed inside the TruPortal System Controller enclosure The univer...

Page 3: ... BRD Input Expansion board 2 TP ADD IO BRD Output Expansion board 3 28058B 02 mounting plate 4 TP ADD IO AL400 enclosure 5 6 32 SEMS nut 8 holes 6 6 32 x 38 in 9 652 mm screw 8 holes Callout Description 1 TP ADD IO BRD Input Expansion board 2 TP ADD IO BRD Output Expansion board 3 28058B 02 mounting plate 4 TP ADD IO AL600 enclosure 5 6 32 SEMS nut 8 holes 6 6 32 x 38 in 9 652 mm screw 8 holes ...

Page 4: ...n place if the rear tamper is not used 1 Remove the cap with the edge of a flat screwdriver 2 Discard the cap The tamper spring can now move freely through the bushing and make contact with the enclosure 3 Secure the enclosure to the mounting surface Callout Description 1 TP ADD IO BRD Input Expansion board 2 TP ADD IO BRD Output Expansion board 3 6 32 x 1 00 in 25 4 mm plastic standoff 4 holes 4 ...

Page 5: ... for the Input Expansion board can be passed through the SNAPP connection Optionally auxiliary power may be used to power the I O Expansion Module The 12 VDC auxiliary output at TB13 supports up to 10 mA Callout Description Callout Description 1 Terminal Block TB 7 TB10 inputs 9 TB13 Auxiliary power input 12 V 2 TB1 tamper off the wall 10 4 mounting holes 0 156 in 04 mm 3 SW1 front tamper switch e...

Page 6: ...ohm in parallel Outputs Two relay outputs Communication SNAPP VBUS Cable requirements 22 AWG 0 644 mm 0 326 mm2 stranded SNAPP bus four conductors VBUS three conductors Input wiring two conductors Power input two conductors Dimensions 5 75 x 2 875 x 0 6 in 146 x 73 x 15 mm Environmental Temperature 32 to 120 F 0 to 49 C Humidity 5 85 RHNC BTU output 4 1 BTU hour Certifications UL294 Listed FCC Par...

Reviews: