Page 2: ... device is in compliance with the applicable requirements and provisions of one or more of the Directives 1999 5 EC 2014 30 EU and 2014 35 EU For more information see www utcfireandsecurity com or www interlogix com 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your loca...

Page 3: ... system with NX 181xx Voice keypads 13 Accessing the NX 595E via a Touch Tone Phone 13 Main Menu Structure 14 Main Menu Explained 15 System Status 15 System Control 15 Intercom Control 15 Output Control 15 Message Bank 16 System Configuration 16 To Configure 17 Main Menu Controls And Examples 19 Menu 1 System Status 19 Menu 2 System Control 20 Partition Control Single Partition 20 Disarm Single pa...

Page 4: ...on Entry Time Configuration 33 Partition Exit time Configuration 34 Alarm and Divert Phone Number Configuration 35 Creating Alarm and Divert Phone Numbers 35 Deleting Alarm and Divert Phone Numbers 36 Voice message recording 37 Exit Message Recording 37 Entry message Recording 38 User Name Voice Recording 38 Zone Name Voice Recording 38 Zone Name library word configuration 39 Partition Name Voice ...

Page 5: ... 46 Status and Partition Control 46 Voice Reporting 47 Users 48 Call Divert 49 Email Reporting 50 Email Reporting examples 50 Access via an Android App 51 Access via an iPhone App 52 Troubleshooting 52 System Status Messages 53 Word Library 55 Index 56 ...

Page 6: ...igence product liability or otherwise Because some jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages the preceding limitation may not apply to you In any event the total liability of UTCFS shall not exceed the purchase price of the product The foregoing limitation will apply to the maximum extent permitted by applicable law regardless of wh...

Page 7: ...led by qualified SERVICE PERSONNEL only The equipment should only be operated with an approved power adapter with insulated live pins Caution Risk of explosion if battery is replaced by an incorrect type Dispose of batteries according to the instructions Contact your service provider for replacement batteries Warranty UTC Fire Security Americas Corporation Inc guarantees this product against defec...

Page 8: ...ons check system status enable disable user codes modify email accounts and voice phone numbers from any standard web browser iPhone app provides access from an easy to use iPhone app without needing to set up port forwarding The NX 595E can interact with you with one or more of these Voice Reporting will call up to three phone numbers and announce alerts in plain English Email Reporting will emai...

Page 9: ...codes Can also be used as a function code for all features NOTE Your security system may have either four 4 digit PIN codes or six 6 digit PIN codes but not a mixture of both Outputs Where external devices are configured These devices can be controlled from your security system Relay An electrically operated switch Common uses include being used to open the front gate to let a visitor in or to tur...

Page 10: ...d enter the required PIN number A single digit selection is required A single digit or multiple digits selection is required This could be a multi digit number e g for Zone 128 press 1 2 8 Navigation keys required to move to the desired menu Start your recording Sub menu of the main menu Sub Sub menu of the main menu ...

Page 11: ... NX 181xx Access to Intercom and Door Release Yes Remote Listen In to NX 181xx Voice keypads Yes Phone Line connection Voice Reporting The NX 595E can phone the user and announce in a human voice selected event conditions This is in addition to alarms signals sent via the NetworX panel to the central monitoring center Users can customize individual name recordings for zones partitions users rooms ...

Page 12: ...to add devices with little or no manual intervention NX 595E Web Interface Once connected to the network users will enjoy the simple web user interface that is supplied with the NX 595E Enter the IP address of your NX 595E into a web browser to access the NX 595E Configuration Server Here the user can configure pin codes arm and disarm partitions view the last 185 event history enter and change al...

Page 13: ...ber of calls rings have been reached When the desired number of calls rings has been reached the NX 595E will grab the phone line and announce the following Enter your code for system access press star to cancel Enter your user master code default master code is 1234 the NX 595E will announce the recorded system name if recorded and list all accessible main menus you can now make your selection as...

Page 14: ...guration 0 1 User Configuration 0 1 1 User Pin 0 1 2 User Partition 0 1 3 User Authority 0 2 Time and Date 0 2 1 Time 0 2 2 Date 0 3 Partition Entry Time 0 4 Partition Exit Time 0 5 Phone number configuration 0 5 1 Alarm Phone Number One 0 5 2 Alarm Phone Number Two 0 5 3 Alarm Phone Number Three 0 5 4 Divert Phone Number One 0 5 5 Divert Phone Number Two 0 5 6 Divert Phone Number Three 0 6 Voice ...

Page 15: ... move back to the main menu Intercom Control Press 3 to access intercom control An intercom call can be initiated from any external touch tone phone and a connection established with the outdoor station individual NX 181xx Voice keypads or all NX 181xx Voice keypads Two way communication is voice switching only one person may speak at any time and the caller has priority Switching between caller a...

Page 16: ...ty system is achieved through this menu Entry and exit times can be adjusted to suit the individual requirements of the system You can record names against users zones partitions rooms and outputs creating an extremely user friendly security system You can also enter delete the three alarm phone numbers and call divert numbers Note voice recording is limited to the first 64 zones Zones 65 and abov...

Page 17: ...s are from 10 seconds to 255 seconds Phone number configuration Alarm phone numbers 1 2 and 3 will receive a voice message upon the activation of certain events from within the security system Selected events are global and will be mapped to all of the three phone numbers Events are selected by your security provider at the time of installation or are accessible via the NX 595E web interface Diver...

Page 18: ...es The NX 595E will announce the system name when first connected To Record Exit message Entry message User name Zone name Partition name Output name Room name System name To move back to System Configuration menu Denotes the ability to configure name using the word library To move back to main menu Note You do not need to wait for the Personal Voice Guide PVG to finish talking before keying in yo...

Page 19: ...l low battery box tamper communication fault Keypad fire panic medical alarm Zone number zone name fire tamper trouble fault loss of wireless supervision low battery 3 Partition Partition name Is On in the away mode Is On in the stay mode Is ready Is not ready All partitions are on in the away mode All partitions are on in the stay mode armed in the stay mode All partitions are ready Zone Number Z...

Page 20: ...nly utilized for arming just the perimeter of the premises Disarm Single partition system How to Disarm a single partition system Step Example Disarming 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press 2 for system control menu Press 2 for partition control menu Press 1 to turn off 3 1st star moves back to system control menu 2nd star moves back to main menu Disc...

Page 21: ...ode only those partitions assigned to that user will be selectable For trouble free multi partition control listen and follow all the voice prompts carefully Away Arm Multi partition system All Partitions How to Away Arm all partitions in a multi partition system Step Example Arm Away All partitions Multi partition 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press...

Page 22: ...rm partition 2 in a Multi partition system 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press 2 for system control menu Press 2 for partition control menu Press 1 to control an individual partition 3 Select an Partition number from 1 8 4 Press 2 To set in the away mode 5 1st star moves back to system control menu 2nd star moves back to main menu Disconnects session...

Page 23: ...isarm partition 2 from within a Multi partition system 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press 2 for system control menu Press 2 for partition control menu Press 1 to control an individual partition 3 Select an Partition number from 1 8 4 Press 1 To turn off 5 1st star moves back to system control menu 2nd star moves back to main menu Disconnects session...

Page 24: ... your security system Step Example Away Arm Stay Arm or Disarm partitions within a Multi partition system 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press 2 for system control menu Press 3 to control zone bypass 3 To control zone bypass select a zone number followed by 4 Press 0 to bypass un bypass Toggles zone from un bypassed to bypassed Or if already bypassed ...

Page 25: ... mode Intercom Call An intercom call can be initiated from any external touch tone phone and a connection established with the outdoor station room 9 individual NX 181xx Voice keypads 1 8 or all NX 181xx Voice keypads 0 Two way communication is voice switching and the calling party has priority Switching between caller and called parties is automatic and is controlled by inactivity silence on the ...

Page 26: ...session 2 Press 3 for intercom control menu Press 2 to commence two way communication mode 3 Select an individual room number from 1 9 9 is outdoor station Press 0 for all rooms 4 1st star moves back to intercom control menu 2nd star moves back to main menu Disconnects session Note Automatic room answering must be enabled at the NX 181xx Voice keypad for listen in feature to function correctly Roo...

Page 27: ...ample Turn output On 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press 4 for output control 3 Select an output number to control from 1 16 followed by 4 Press 1 to turn output On 5 1st star moves back to output control menu 2nd star moves back to main menu Disconnects session How to Control connected outputs Step Example Turn output Off 1 PIN Call the NX 595E via ...

Page 28: ...k Press 1 to record an exit message 3 Press to record a new message 4 Record 10 second Exit message after the beep first time only 5 1st star moves back to message bank menu 2nd star moves back to main menu Disconnects session Entry Message How to Record an Entry Message Step Example To record an entry message for the first time 1 PIN Call the NX 595E via an offsite touch tone phone to begin the s...

Page 29: ...ns to users determines which sections partitions of the security system a user may access The authorization level determines the options available to that user user authorization is where you would alter and increase a users authority to become a Master Code Master codes can only create delete or modify user codes with equal or less authority than themselves User PIN Creating How to Configure set ...

Page 30: ...ser 4 has control of both partitions 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press 0 for system configuration menu Press 1 for user configuration menu Press 2 for user partition configuration 3 Select a user number followed by e g user 4 4 Press the partition number to change selection e g deselects partition 2 partition partitions can be toggled on off 5 1st ...

Page 31: ... 595E via an offsite touch tone phone to begin the session 2 Press 0 for system configuration menu Press 1 for user configuration menu Press 3 for user authority configuration 3 Select a user number followed by e g User 6 4 Press the option number from 1 8 to change selection e g option 4 Master code Refer to Table 1 below for complete list of selectable user authority options 5 1st star moves bac...

Page 32: ...fsite touch tone phone to begin the session 2 Press 0 for system configuration menu Press 2 for time and date configuration menu Press 1 for time configuration 3 Select the hours value from 1 12 followed by e g 9 o clock 4 Selects the minutes value followed by e g 30 minutes 5 Press 1 to set AM time e g AM time Press 2 to set PM time Note Time change is complete move to step 6 only if you wish to ...

Page 33: ...255 seconds How to Adjust the partition Entry time Step Example Adjust partition entry times 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press 0 for system configuration menu Press 3 for partition entry times 3 Select an partition number to configure from 1 8 4 Select a new partition entry time 10 255 seconds followed by 5 1st star moves back to step 3 select an p...

Page 34: ... 255 seconds How to Adjust the partition Exit time Step Example Adjust partition entry times 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press 0 for system configuration menu Press 4 for partition exit times 3 Select an partition number to configure from 1 8 4 Select a new partition exit time 10 255 seconds followed by 5 1st star moves back to step 3 select an par...

Page 35: ... provider at the time of installation or are accessible via the NX 595E web interface Divert phone numbers 1 2 and 3 will be called when an intercom call is initiated from an outdoor station The outdoor station must be interfaced with the NetworX security system via the NX 595E The NetworX security system must also be in the armed condition Creating Alarm and Divert Phone Numbers How to Enter Phon...

Page 36: ...ation menu Press 5 for phone number configuration 3 Select the number you are editing Press 1 to configure alarm phone number 1 Press 2 to configure alarm phone number 2 Press 3 to configure alarm phone number 3 Press 4 to configure divert phone number 1 Press 5 to configure divert phone number 2 Press 6 to configure divert phone number 3 4 Press 0 followed by to disable alarm divert phone number ...

Page 37: ...is is ideal when monitoring multiple sites Apart from voice recordings zones partitions outputs and rooms can be configured using pre recorded words from the word library You may string up to eight words together to achieve your desired description Note Please note that voice recording is limited to the first 64 zones pre recorded library words must be used for all additional zones above zone 64 E...

Page 38: ...Voice keypads 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press 0 for system configuration menu Press 6 for voice message recording Press 3 to record or configure a user name 3 Select a user number to record followed by 4 Press to record a new user name 5 Record 3 second user name after the beep 6 1st star moves back to step 4 select a user number to record 2nd st...

Page 39: ...ht library words can be strung together to achieve your desired phrase 4 Press 2 To configure a new zone name 5 Select library word one followed by e g Dining word 53 Select library word two followed by e g Room word 117 Select library word three followed by e g Sensor word 121 Note If your system is configured with NX 181xx Voice keypads you will be prompted to either copy changed recordings or c...

Page 40: ...nfigured with NX 181xx Voice keypads you will be prompted to either copy changed recordings or copy all recordings when exiting this menu Copy changed recordings will only add the latest recordings whilst selecting copy all recordings will overwrite all recordings new and old Please contact your security provider to verify how your system is configured For multiple recordings press once at step 6 ...

Page 41: ...ed recordings will only add the latest recordings whilst selecting copy all recordings will overwrite all recordings new and old Please contact your security provider to verify how your system is configured For multiple recordings press once at step 6 which will take you back to step 4 this will allow additional recordings without exiting the system Room Name Voice Recording How to Record a room n...

Page 42: ...recordings press once at step 6 which will take you back to step 4 this will allow additional recordings without exiting the system System Name Voice Recording How to Record a system name to the NX 595E Step Example To record a system name for the NX 595E 1 PIN Call the NX 595E via an offsite touch tone phone to begin the session 2 Press 0 for system configuration menu Press 6 for voice message re...

Page 43: ...re is not in use move to step 4 to disconnect the intercom session 4 Disconnects session How to Answer an alarm call from your security system Step Example Answering an alarm call from your security system at one of the three alarm phone numbers 1 Answer the incoming call NX 595E will announce Call from system name 0 6 8 Alarm condition active Enter your code for system access Press star to cancel...

Page 44: ...ur installer for assistance Figure 1 Alternatively you may enter NX 595E directly into the browsers address window as per Figure 2 This feature is dependent on your network Figure 2 You may also connect using SSL or Secure Sockets Layer by typing https instead of http in the address bar for higher security communications between your browser and the NX 595E SSL connections may be slightly slower d...

Page 45: ...gn in page To access the main menu enter the username and password as supplied by your security provider These details should be on the back of this manual Note Username is case sensitive Access Levels There are two access levels available to users master code or standard user codes Master codes have greater authority and are able to access more features Main Menu Master User Code Partition 1 ...

Page 46: ...tition s click on the partition number s in the On Away Mode row To fully arm all partitions click the All button in the On Away Mode row The corresponding partition number s will illuminate red indicating a successful arm of that partition To stay arm partially turn on an individual partition s click on the partition number in the On Stay Mode row To stay arm all partitions click the All button i...

Page 47: ...the internal event log to what is currently displayed Next Will display the next consecutive event from the internal event log to what is currently displayed Most Recent Will display the current latest existing event from the internal event log Current System faults will be displayed in the System Status window and the systems past 185 event log can be accessed via the prev previous button in the ...

Page 48: ...lly four digits in length but can be configured to be six digits in length if this level of security is required contact your security provider to enable 6 digit PINs The authorization level determines the options available to that user user authorization is where you would alter and increase a users authority to become a Master Code Master codes can only create delete or modify user codes with eq...

Page 49: ... disabled mute menu option 4 After a called party answers the phone the NX 595E will announce Intercom call from system name Press hash to answer Press star to cancel Once the call is connected a bi directional conversation can take place and the called party has the ability to operate the built in relay by pressing the 0 key on their phone keypad As an example of this features use the relay may b...

Page 50: ... Server Settings These settings are required if you want event reporting emails to come from your email account Otherwise leave these sections blank and the NX 595E will attempt to use a server without further configuration Email Reporting examples User Arming Security Report From Account 0001 Turn on Away Mode Partition 1 Fred Time 11 55 AM Date 19 Jun Panic Button on keypad Security Report From ...

Page 51: ...o the Google PlayTM store 2 Search for xConnect 3 Install the app 4 Click the icon on your device to launch it 5 Click to add a new account 6 Enter the details of your security system this should be on the back of this manual if not please contact your security installation company or builder for assistance The serial number is also printed on the back of the NX 595E unit inside the NetworX enclos...

Page 52: ...k to add a new account 6 Enter the details of your security system this should be on the back of this manual if not please contact your security installation company or builder for assistance The serial number is also printed on the back of the NX 595E unit inside the NetworX enclosure Opening the enclosure may cause a tamper alarm to sound 7 Click Sites button to save the details 8 Click the name...

Page 53: ... away mode Is on in the stay mode This partition is armed in the stay mode Is ready This partition is secure and ready to be armed Is not ready This partition is NOT ready to be armed a zone is not secure All partitions are on in the away mode All partitions in this multi partition system are armed in the away mode All partitions are on in the stay mode All partitions in this multi partition syste...

Page 54: ...g AC power fail A remote power supply has lost its electricity power Box tamper An expanders cabinet tamper input has activated Keypad Fire alarm A fire alarm has been activated at the keypad Panic A panic alarm has been activated at the keypad Medical A medical alarm has been activated at the keypad ...

Page 55: ...airs 18 Eighteen 56 Driveway 94 Lift 132 Storage 19 Nineteen 57 Duress 95 Light 133 Study 20 Twenty 58 East 96 Living 134 Temperature 21 Thirty 59 emergency 97 location 135 tennis 22 Forty 60 Exterior 98 Master 136 Toilet 23 Fifty 61 Family 99 Medicine 137 Training 24 Sixty 62 Fan 100 Meeting 138 T V 25 Seventy 63 Fence 101 Motion 139 Upstairs 26 Eighty 64 Fire 102 Night 140 User 27 Ninety 65 Forc...

Page 56: ...2 Divert phone numbers 1 2 3 18 E E Mail Reporting 50 Entry message 18 Entry Message 16 Event History 15 Exit message 16 18 H How to Check system status 19 I Intercom control 25 Intercom Control 15 L Listen in to a NX 181xx Voice keypads front door station 25 M Main Login Menu Web Master User Code 45 Main Login Menu Web Standard User Code 46 Message Bank 16 28 N Navigating to the NX 595E 44 O Outp...

Page 57: ...Control 15 20 System name 18 System Name voice recording 42 System status 19 System Status 15 T Time 17 Time and date 17 Time and Date Configuration 32 To commence listen in mode 15 To commence two way communication mode 15 To Control Zone Bypass 15 Turn off a selected output 27 Turn on a selected output 27 U User Authority 17 User configuration 16 User Configuration 29 User name 18 User Partition...