background image

 

IS-ZW-TSTAT-300 

Advanced Thermostat 

Operation Guide 

Content 

Contact information   1

 

Description   2

 

Home screen   3

 

Menu screen   3

 

Program screen   5

 

Manual screen   6

 

Initial settings   7

 

Auto-run program   7

 

Other functions   8

 

Communicating thermostat   9

 

Specifications   10

 

 

Contact information 

For contact information, see www.interlogix.com. 
© 2013  UTC Fire & Security Americas Corporation, Inc.   
Interlogix is part of UTC Climate Controls & Security, 
a unit of United Technologies Corporation.  
All rights reserved.  

P/N 1069511 • REV B • ISS 12FEB13 

Summary of Contents for IS-ZW-TSTAT-300

Page 1: ...nitial settings 7 Auto run program 7 Other functions 8 Communicating thermostat 9 Specifications 10 Contact information For contact information see www interlogix com 2013 UTC Fire Security Americas Corporation Inc Interlogix is part of UTC Climate Controls Security a unit of United Technologies Corporation All rights reserved P N 1069511 REV B ISS 12FEB13 1 ...

Page 2: ...or metallic device it will scratch the screen Figure 1 IS ZW TSTAT 300 LINK RADIO TARGET TEMP Top cover Bottom cover Wire terminals MODE button FAN button Menu button Prog button Reset button HVAC switches Save Energy button Power grid status indicator Touch screen Control screens Before you operate the thermostat you should get familiar with these basic control screens All the thermostat function...

Page 3: ...ator To set a mode press the MODE button on the side of the thermostat The thermostat will step through the HEAT OFF and COOL modes in order The LCD display indicates the mode you are in Menu screen To display the Menu screen press the Menu button Figure 3 Menu screen Time Filter timer Temperature swing Chirp icon Home icon Lock icon HVAC setup Day Calibration control F C indicator Differential Us...

Page 4: ... is 1 0 F Touch the Home icon to return to the MENU screen DIFF differential This feature is used for two stage normal or heat pump with aux only the feature is not on screen for single stage The differential is the number of degrees between the room temperature and the target temperature at which the second stage will be used The default is 2 F Touch DIFF Use the arrows to set the differential We...

Page 5: ...tem Figure 4 Program screen Program time Time slot Temperature up arrow Temperature down arrow Home icon Program day Copy program Day Touch to set the day of the week for which you want to program target temperatures Time slot Touch to set the time slot MORN DAY EVEN or NITE you want to program Program time Touch to set the time of day you want the time period to start Left arrow goes back right a...

Page 6: ...e target is set the same as the programmed target for that period the word TEMPORARY will not display HOLD Touch to operate the thermostat as a manual thermostat This will hold the target temperature you set indefinitely until you turn HOLD off Use care when using the HOLD function as the program is now bypassed To set a hold target temperature touch HOLD and use the icons to select your hold temp...

Page 7: ...ve the time selection forward or backward until it displays the correct time You can touch and hold for faster setting To select F or C for the display touch the F to toggle to C or touch the C to toggle to F To set the audible chirp touch the musical note icon to toggle between chirp or no chirp To return to the Home screen touch the Home icon Auto run program The thermostat comes preprogrammed w...

Page 8: ... program MORN DAY EVEN or NITE touch the time slot area to cycle through to the desired period To select the desired start time of that time slot touch the time arrows to display the desired starting time Hold the arrow down for fast time scrolling To select the desired target temperature for that time slot touch the arrows to display the desired temperature To copy one day s programming to the ne...

Page 9: ...ET button reboots the thermostat processor It does not effect the user programs that have been stored in permanent memory Simple screen This display mode limits the amount of information on screen and limits the functions to just the arrows and the Save Energy button Hold down the Prog button for 10 seconds to access the limited display screen Hold down the Prog button for 10 seconds to leave the ...

Page 10: ...VAC system and home conditions To insert a USNAP radio module power off the thermostat insert the radio module in either slot on the back of the thermostat and then power up the thermostat To connect to a network follow the instructions that come with the USNAP module Caution Do not insert or remove USNAP radio modules if power is on This can damage the thermostat or radio modules Specifications V...

Page 11: ...s no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the e...

Page 12: ...12 IS ZW TSTAT 300 Advanced Thermostat Operation Guide ...

Reviews: