background image

 

P/N 466-

 

 

3 / 6 

Settings Screen 

Touch the Settings icon 

 on the Main screen and the 

Settings screen appears. 

features.  

Typical status indicators (excluding light screen): 

 

Gold - A button is selected. 

 

Blue - Buttons not selected. 

Use the scroll buttons to see all of the options (below): 

Event History 

- Touch the Related Show button to view 

system events. 

Direct Bypass 

- Touch the Related button to bypass a sensor.  

Panel Status 

- Touch the Related Show button to display the 

status of your security system. 

Smoke Reset 

 Is displayed only after wired smoke detectors 

have activated and require resetting. Touch to reset smokes 

when displayed. 

 

Change Partition 

- Touch the Related button to change 

partitions. 

Chime - 

Touch the On or Off button to toggle the touch screen 

chime feature on or off. This feature will enable this touch 
screen to beep when a certain door opens. Ask your security 
provider which doors are programmed to chime when opened. 
Refer to the security panel documentation for information on 
this feature.

 

Keypress Volume 

- Touch the arrow buttons to adjust this 

not controlled by this setting. 

Beep Volume

 - Touch the arrow buttons to adjust this touch 

beep volume level. The siren sounds are not 

controlled by this setting. 

Brightness 

- Touch the arrow buttons to adjust the brightness 

 

Default screen 

screen saver mode. Select Blank to have the screen and LED 
go dark after a period of inactivity. Otherwise, the default will 
be the Main screen and the screen will always be lit.  

The touch screen will automatically blank daily at 2:00 AM for 
60 minutes. 

Calibration 

- The touch screen typically does not need to be 

calibrated. However, if the touch screen buttons do not 
respond correctly, touch the Show button to access the 
Calibration screen. To calibrate the touch screen, touch the + 
icons in the corners of the screen using a soft, fine point. 

Help 

-

 

Touch the Help button to access the Help menu, which 

displays a list of help topic buttons. Touch the buttons for 
information on a given topic. 

Code Access Required 

(

CAR

)

 

 When this option is enabled, 

information displayed is limited and a passcode is required for 
any access. Enable this setting when the touch screen is 

located in a less secure area, such as a garage. If this device 
is located in areas that are less secure, be sure your service 
provider has Quick Arm and Quick Exit programmed to off.  

Programming 

Touch the Settings icon

 

 on the Main screen and the 

Settings screen appears. 
Touch the down scroll button down until you see this screen: 

 

Touch the enter button next to Programming.  

You will then be prompted enter your access code, after which 
the System Programming screen will appear ( System Master 
and Partition Master Code only. User access codes will not 
allow entry into System Programming). 

 

User Codes 

Uses this screen to change or delete codes or modify attributes 
and permission associated with a code. Each user (identified 
by a user number must have a unique code).  

 

Summary of Contents for Concord

Page 1: ... The product accessory bag contains items that could be choking hazards Please keep away from small children ATTENTION Le sachet d accessoires produit contient des Main Screen The Main screen is the display shown most of the time in normal operation All operations begin at and inactivity reverts to this screen Access the Main screen Via the Close icon display to the previous screen Depending on wh...

Page 2: ... icons indicate the armed status of the security system PRESS TO ARM When the icon shows PRESS TO ARM touch to access the Arm screen or PRESS TO DISARM Depending on your arming level one of these icons will appear Press to disarm your system Enter your code in the keypad screen that appears If you enter an incorrect code press the Clear button and enter the correct code Arming Screen When you touc...

Page 3: ...after a period of inactivity Otherwise the default will be the Main screen and the screen will always be lit The touch screen will automatically blank daily at 2 00 AM for 60 minutes Calibration The touch screen typically does not need to be calibrated However if the touch screen buttons do not respond correctly touch the Show button to access the Calibration screen To calibrate the touch screen t...

Page 4: ...em Programming screen press the Options button The options presented are those available to change for the user selected upon entering Programming The user shown below can edit Downloading and Chime on Close If your system is equipped with either a voice only module or phone interface voice module you will see the Voice Chime selection and volume controls Set Up Schedules On the System Programming...

Page 5: ...a glance The table below explains LED behavior Table 1 Status LED LED System status Solid blue while backlights are on Primary power present Fading blue Primary power failure Off Screen saver active Cleaning If necessary use a soft cloth to clear smudges on the touch screen Do not use glass cleaner Maintenance and support A qualified technician should check this system every 3 years Disposal Dispo...

Page 6: ...y install security related products For more information on product warnings refer to firesecurityproducts com policy product warning or scan the code Contact information For general information see www interlogix com For customer technical support see www interlogix com customer support or call 1 855 286 8889 7 United Technologies Corporation Interlogix is part of UTC Building and Industrial Syst...

Reviews: