ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide
25
Alarm control
3-Alarm Control
XX,Menu:
This menu provides options for arming/disarming using the access control
features.
Alarm group
XX,Alarm Group 1
*-Dis, Grp:
Alarm groups may be assigned to doors to restrict alarm control from that door to
the areas assigned to the alarm group.
Restrictions on the level of alarm control available (e.g. Disarm Only), and the
time period (timezone) when the alarm control functions can be performed, may
also be specified in the alarm group.
See also Advisor Master Installer menu 5, Alarm Groups.
Alarm control
XX, Reader Has No Alarm Control
*-Change,Opt:
Specify what type of alarm control will be available for the door/reader.
• 0: Reader Has No Alarm Control. It is not possible to arm/disarm using the
reader.
• 1: Alarm Control on 1st Badge. Presentation of a valid card at the reader will
disarm the areas in the alarm group on first badge. Badging three times will
arm the areas.
• 2: Alarm Control on 3rd Badge. Presentations of a valid card three times
arm/disarms the areas in the alarm group.
• 3: Alarm Control with Buttons. Not available in Europe.
• 4: Always Alarm Control (IN=OFF OUT=ON). Presentation of a valid card at
the IN reader disarms the areas in the alarm group. Presentation of a valid
card at the OUT reader arms the areas in the alarm group.
• 5: Alarm control with regions. The last user leaving the region assigned to
door automatically arms the area, and the first user entering the region
disarms it. This option is similar to option
“Alarm control on 1st badge”, but
works only for the last and the first user in the region.