ATS125x/1260 Four-Door/Four-Lift DGP Programming Guide
1-DGP options
DGP options are valid for all doors or lifts on the selected ATS125x/1260.
Note:
Whenever, in DGP options, XX is displayed, the XX should be replaced by
the 1
st
door number available for this AST125x/1260.
Output controllers
XX, Output Controllers 0
*-Dis, Ctrl:
Enter the number of output controllers fitted to ATS125x.
• 0: Disabled. No clocked output card, but there are four open collector outputs
available on the DGP for an ATS1810 4-way relay card. These have outputs
5 to 8 assigned for the selected DGP address).
• 1 to 8: Number of output controllers connected.
Batch Number (range 1 to 40)
Batch Number (Range 1 to 40)
Batch:
This setting specifies the card batches that are programmed for this DGP. A
batch is defined by a System code, a range of cards, the first card number and
the first user code.
Card Batch Overlap (nn)
*-Confirm
When card batches overlap, a message will be displayed to indicate. Overlaps
will occur when if in a system code, card numbers are repeated or when users
are assigned more than one card number. Press [MENU*] or [*] to confirm when
an overlap is required.
System Code
System code: Disabled
SC :
Register the System code for this batch of cards (maximum of 6 digits).
Start Card Number
Start Card Number: 0
CN:
Enter the number of the first card that is used for this batch.