P/N MAINST-

ATS1197 (ML) • REV D • ISS 11JUN19 

 

5 / 14 

Unsecured 

When an unsecured card is badged on a reader using 
the magnetic stripe format, 32 bit data is transmitted. 

Offline 

 

Reader protocol 

Card format 

Wiegand 

Magnetic stripe 

Secured 

When badged on a 
reader, 26 or 27 bit data 
is transmitted, 
depending on whether 
the card is programmed 
as Wiegand 26 bit or 
Aritech Wiegand ASC. 

When badged on a reader, 
Magnetic stripe format 
data is transmitted. 

A "card present" signal is 
available on the relay 
output (violet wire), if 
selected in menu option 8-
Open collector output. 

Unsecured 

When badged on a 
reader using the  
Wiegand protocol, 
Aritech Wiegand ASC 
data is transmitted. 

When badged on a reader 
using the magnetic stripe  
protocol, Magnetic stripe 
data is transmitted. 

Specifications 

Supply voltage 

8.5 to 14.0 V 

Maximum operating current 

110 mA at 13.8 V

 

Normal operating current (all areas 
armed) 

40 mA at 13.8 V

 

Open collector output (OUT terminal) 

14 V

 max. at 50 mA max. 

Dimensions (W x H x D) 

140 x 121 x 22 mm 

Operating temperature 

−40 to +50°C 

Relative humidity 

< 95% non condensing 

Regulatory information 

Manufacturer 

UTC Fire & Security Americas Corporation, Inc. 
3211 Progress Drive, Lincolnton, NC, 28092, USA 

Authorized EU manufacturing representative: 
UTC Fire & Security B.V. 
Kelvinstraat 7, 6003 DH Weert, Netherlands 

Product warnings 
and disclaimers 

 

THESE PRODUCTS ARE INTENDED FOR SALE 
TO AND INSTALLATION BY QUALIFIED 
PROFESSIONALS. UTC FIRE & SECURITY 
CANNOT PROVIDE ANY ASSURANCE THAT 
ANY PERSON OR ENTITY BUYING ITS 
PRODUCTS, INCLUDING ANY “AUTHORIZED 
DEALER” OR “AUTHORIZED RESELLER”, IS 
PROPERLY TRAINED OR EXPERIENCED TO 
CORRECTLY INSTALL FIRE AND SECURITY 
RELATED PRODUCTS. 

For more information on warranty disclaimers and 
product safety information, please check 

https://firesecurityproducts.com/policy/product-
warning/

 or scan the QR code. 

Certification 

   

EN 50131 

EN 50131-1 System requirements 
EN 50131-3 Control and indicating equipment 

Security Grade 3, Environmental class II 

Tested and certified by Telefication B.V. 

 

UTC Fire & Security hereby declares that this 
device is in compliance with the applicable 
requirements and provisions of all applicable rules 
and regulations, including but not limited to the 
Directive 2014/53/EU. For more information see: 
www.utcfssecurityproducts.eu 

 

2012/19/EU (WEEE directive): Products marked 
with this symbol cannot be disposed of as 
unsorted municipal waste in the European Union. 
For proper recycling, return this product to your 
local supplier upon the purchase of equivalent 
new equipment, or dispose of it at designated 
collection points. For more information see: 
www.recyclethis.info 

Contact information 

www.utcfireandsecurity.com or www.interlogix.com 

For customer support, see www.interlogix.com/customer-
support.
 

DE: Installationsanleitung 

Montage des Geräts 

1.  Trennen Sie die Einbruchmeldezentrale oder den 4-

Tür-

Controller von der Spannungsversorgung. 

2. 

Entfernen Sie die beiden Schrauben für die Vorderseite 
unten an dem BDT (siehe Abbildung 1) und nehmen Sie 
anschließend die BDT-Rückplatte ab. Legen Sie die 
Schrauben beiseite, um das BDT später zu sichern. 

3.  Halten Sie die BDT-

Rückplatte (mit der Feder des 

Sabotagekontakts nach oben) an die Montagestelle, um 
die Position der Befestigungslöcher und der Verkabelung 
zu ermitteln (die Montage auf einer Oberfläche aus Metall 
kann zu einem reduzierten Kartenleseabstand führen).  

4. 

Befestigen Sie die Rückplatte mit vier Schrauben an einer 
flachen Oberfläche (in das am nächsten zur Feder des 
Sabotagekontakts gelegene Loch muss eine Schraube 
eingesetzt werden, sodass der Schalter ordnungsgemäß 
arbeiten kann). 

5. 

Schließen Sie das Kabel, wie erforderlich, ab (siehe 
Verkabelungsdetails weiter unten). 

6. 

Für den Online-Modus stellen Sie die BUS-Adresse (DIP-
Schalter 1 bis 4) ein. Für den Online-Modus stellen Sie 
den TERM-Schalter (DIP-

Schalter 5) nach Bedarf ein. Für 

den Offline-Modus muss der TERM-Schalter 
ausgeschaltet sein (nach oben). Weitere Details finden Sie 
im Abschnitt mit den DIP-Schaltereinstellungen. 

7. 

Befestigen Sie das BDT an der Rückplatte, indem Sie 
zunächst die obere Kante einsetzen und dann das BDT 
flach auf d

ie Rückplatte aufsetzen. Damit das System 

ordnungsgemäß funktioniert, muss der rückwärtige 
Sabotageschalter geschlossen sein. Stellen Sie sicher, 
dass die Feder an der Rückplatte auf dem Auslöser des 
Sabotagekontakts aufliegt (der aus dem Kunstharz hinten 
im BDT austritt), wenn sich das BDT in Position befindet. 

8.  Befestigen Sie das BDT mit den beiden Schrauben an der 

Rückplatte, die Sie in Schritt 2 entfernt haben. 

9.  Verbinden Sie die Einbruchmeldezentrale oder den 4-

Tür-

Controller mit der Spannungsversorgung. 

10. 

Für den Online-Modus verwenden Sie ein LCD-BDT auf 
dem BUS (oder die Managementsoftware des Systems), 
um die Abfrage zu programmieren und die erforderlichen 
Optionen für das neue BDT einzustellen. Wichtig: Das 

Summary of Contents for ATS1197

Page 1: ...s 7 Mount the RAS on the back plate by engaging the top and then lowering the RAS to be flat against the back plate The rear tamper switch must be sealed for the system to work correctly Ensure that the back plate tamper spring rests on the tamper switch actuator protruding from the resin in the back of the RAS when the RAS is in position 8 Fix the RAS to the back plate using the two screws remove...

Page 2: ...buzzer control Wire open or 5 to 12 V buzzer off absolute maximum is 14 V Wire grounded 0 V buzzer on Brown Application depends on selection of RAS menu option 2 Offline LED control See programming Colour Application Yellow Application depends on selection of RAS menu option 2 Offline LED control see programming When not used for two wire LED control yellow wire may be used for RTE input when onli...

Page 3: ... the bus is faulty usually cabling Tx The red Tx LED flashes to indicate the RAS is replying to polling from the control panel If the Rx LED flashes but the Tx LED does not the RAS is not programmed to be polled in the control panel or is addressed incorrectly Configuring the ATS1197 RAS To configure the RAS 1 Press 19 Enter followed by 3 Enter 2 Type the required RAS address 2 to 16 followed by E...

Page 4: ... and disables the use of reader configuration option cards at the reader If an installer wishes to prevent the modification of the reader setup by configuration card this option should be disabled Menu 10 RTE Egress The RAS is fitted with Request To Exit RTE control yellow wire The open collector output violet wire may be used to control a door relay RTE is only available in online mode There are ...

Page 5: ...marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info Contact information www utcfireandsecurity com or www interlogix com For customer support see www i...

Page 6: ...nschluss AUX PWR von einer AME oder einer Nebenmelderversorgung Schwarz 0 V Gleichspannung Grün D0 D Clock kann für D0 Wiegand Daten D RS485 Daten Magnetstreifen Clock verwendet werden Normale Betriebsspannung 0 bis 5 V absolutes Maximum 12 V Weiß D1 D Daten kann für D1 Wiegand Daten D RS485 Daten Magnetstreifendaten verwendet werden Normale Betriebsspannung 0 bis 5 V absolutes Maximum 12 V Das BD...

Page 7: ...n damit die Scharfschaltung des Systems an Die Bereiche müssen unscharfgeschaltet werden damit auf die Optionen im Errichterprogrammiermenü zugegriffen werden kann Fehlerbehebung Allgemeine Störungen Keine LED Anzeige oder Hintergrundbeleuchtung für die Tastatur aktiviert Überprüfen Sie sowohl am BDT als auch am Netzteil die Kabelverbindungen für 13 8 und 0 V Spannungsversorgung Überprüfen Sie den...

Page 8: ...der auf Minus 0 V LED 1 grün ein Ader offen oder an 5 bis 14 V LED 1 aus Gelbe und braune Ader auf Minus 0 V LED 1 leuchtet gelb Nicht zulässig bei Verwendung mit UTC Produkten Bei der 1 Draht LED Steuerung steuert die braune Ader die zweifarbige LED 1 grün rot Ader auf Minus 0 V LED 1 grün ein Ader an 5 bis 15 V LED 1 rot ist aktiv Offen oder Ader an 2 5 V LED 1 aus Menü 3 Anzeige Gültige Karte b...

Page 9: ...erät programmiert wurden Es wird das 4 Byte lange Sicherheitspasswort verwendet Datenübertragung In den folgenden Tabellen werden die Formate aufgelistet die der Kartenleser zum Übertragen von Daten verwendet Die Formate werden durch folgende Faktoren beeinflusst Online oder Offline Modus des Lesers Menü 5 Protokolloptionen Wiegand oder Magnetstreifen Menü 16 Sicherheitsmodus Gesichert oder Ungesi...

Page 10: ...ei cavi Il montaggio del dispositivo su una superficie metallica può comportare una riduzione della portata di lettura 4 Fissare la piastra posteriore su una superficie piana utilizzando quattro viti Per il corretto funzionamento dell interruttore antimanomissione il foro più vicino alla molla antimanomissione deve essere occupato da una vite 5 Terminare il cavo in base alle esigenze vedere più av...

Page 11: ...u 2 della RAS Controllo LED fuori linea Vedere la sezione relativa alla programmazione Giallo L applicazione dipende dalla scelta dell opzione di menu 2 della RAS Controllo LED fuori linea Vedere la sezione relativa alla programmazione Quando non utilizzato per il controllo LED a due cavi il cavo giallo può essere utilizzato per le seguenti applicazioni Ingresso RU quando in linea con l ATS Colleg...

Page 12: ...n lo specifico sistema LED Rx e Tx I LED Rx e Tx visibili sulla scheda dei circuiti quando il coperchio posteriore di plastica viene rimosso semplificano la diagnosi dei guasti Rx Il LED giallo Rx lampeggia per indicare la ricezione dei dati di interrogazione inviati dalla centrale al bus del sistema Se il LED non lampeggia la centrale non è operativa oppure il bus è guasto generalmente si tratta ...

Page 13: ...al minuto per indicare che la RAS è collegata e funziona correttamente Se la protezione antimanomissione dell ATS1197 è attiva il byte di dati non verrà inviato opzione disattivata per impostazione predefinita Menu 8 uscita A C Selezionare una delle opzioni seguenti Relè varco solo modalità in linea l uscita open collector si attiva attiva bassa quando il segnale di varco aperto viene inviato all ...

Page 14: ...iche Tensione di alimentazione Da 8 5 a 14 0 V Corrente massima di funzionamento 110 mA a 13 8 V Corrente normale di funzionamento tutte le aree inserite 40 mA a 13 8 V Uscita open collector terminale OUT 14 V max a 50 mA max Dimensioni L x A x P 140 x 121 x 22 mm Temperatura di esercizio Da 40 a 50 C Umidità relativa 95 senza condensa Informazioni sulle normative Produttore UTC Fire Security Amer...

Reviews: