© 2018 United Technologies Corporation.
P/N 1073494A
• REV 00.00 • ISS 4JUL18
Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved.
ACL800FL-CONV-W - RS485 to TCP/IP
converter - Installation Manual
Description / Operation
The ACL800FL-CONV-W is highly integrated serial to ethernet
converter that enables you to connect any UTC biometric
reader over a local LAN network or over the Internet to your
computer. Configuration of the IP address, dynamic DNS,
TCP/UDP ports can be done from browser or from the ACL800
BioManager software. The software is capable to automatically
search IP addresses of the converters, as well as the serial
numbers of the biometric readers.
The device is already preset for use with the biometric readers.
Specifications
Power Supply:
12VDC, 100 mA
Network interface:
10 BaseT, Half duplex
RS485 interface:
38400 Bps (8 bit data, no parity, 1 stop bit)
“Find Portals” by
ACL800 BioManager
Yes
POE:
No
Security:
Dedicated IP or/and MAC address
DDNS support:
Yes
Visual
LED
signalization:
TCP/UDP packets
DHCP client:
Yes
Default IP address:
192.168.1.100
Reset IP to default:
Yes, by tact switch
PCB size:
32 x 86 mm, 4 fixing holes dia. 3 mm
Housing:
DIN Rail or Wall mount, plastic, size 2 unit
Operating
temperature:
0 to +40°C, noncondensing
Dimension
90 x 37 x 33 mm
Wiring
Figure 1: Wiring instructions
LED
1- TCP Packets
2- UDP Packets/Reset IP
Termination resistor