Press and hold the Enter button for approximately five 
seconds. The following screen will appear: 

 

The emulated keypad works and functions the same as the 
600-1070-E keypad. To enter programming mode press 8, 
followed by a valid installer or master code, 0, 0.  

For additional details on programming with the touchscreen, 
see 

Concord 5 in TouchScreen Quick Operation Guide

.  

To exit programming, press the “Exit “ button or press and hold 
the top white bar where info is displayed. 

Verifying touch screen bus enrollment and panel 
programming touch screen options 

Enter programming emulation mode as described above. For 
more information on alphanumeric touch pad operation, refer 
to the Concord 4 Installation Manual. 

1.  Go to the Bus Device Programming section in Concord 

(System Programming / Security / Accessory Modules / 
Bus Devices (shortcut 10,000 for unit ID 0). 

The display shows the lowest device address and it’s ID.  

This example shows what a device address display may 
look like: 

UNIT - ID 
02110185* 

* The 8-digit SuperBus ID number is also located on a 
label on the back of the alphanumeric keypad. 

2.  Cycle through all bus device addresses until the 

alphanumeric keypad appears. 

3.  To program the following touch screen options, choose the 

touch screen bus device address. 

Change ID 

With this menu, change the bus device ID number when 
replacing a defective bus device. 

To change a device ID: 

1.  With the display showing the desired bus device, press #, 

#.  

The display shows 

DEVICE ID 

(current ID). 

2.  Enter the ID of the new bus device.  

The display flashes the entered selection. Press #

 

and the 

display shows the new setting. 

3.  Exit programming mode. 

4.  Remove AC and battery power from the panel. 

5.  Replace the defective bus device with a new one. 

6.  Apply AC and battery power to the panel. 

Partition assignment 

With this menu, assign bus devices to work in the desired 
partition. 

To assign bus devices to partitions: 

1.  With the display showing the desired bus device, press #. 

2.  Press A

 

or B

 

until the display shows 

DEVICE PTN 

and 

then press #. The display shows 

PARTITION ASSIGN. 

3.  Press 1

 

to 6

 

to select the desired partition.  

The display flashes the entered selection.  

4.  Press #

 

and the display shows the new setting. 

Status beeps 

Option not used with touch screen. Touch screen status beeps 
can be changed in the touch screen settings menu. 

Key beeps  

Option not used with touch screen. Touch screen key beeps 
can be changed in the touch screen settings menu. 

Panel sensor text programming guidelines 

Programming for touch screen At-A-Glance (AAG) icons 

For best results, do not program sensor names that contain a 
combination of the words Door, Window, and/or Motion.  

The designator words Door, Window, or Motion should be 
programmed within the first three words of the sensor text 
sequence. If not, the wrong AAG association may occur. 

Door

 - Sensor names 

must contain “Door” (item number 50). 

When programming a name for a sensor, enter 50 and the 
word Door is added to the text. These sensors should be a 
sensor group that requires a restoral.  

Window 

- Sensor names 

must contain “Window” (item number 

183). When programming a name for a sensor, enter 183 and 
the word Window is added to the text. These sensors should 
be a sensor group that requires a restoral. 

Motion

 - 

Sensor names must contain “Motion” (item number 

119). When programming a name for a sensor, enter 119 and 
the word Motion is added to the text. These sensors should be 
a sensor group that does not require a restoral. 

Property 

- Any sensor that does not contain the words Door, 

Window, or Motion. They may be a restoral or non-restoral 
sensor. 

If a sensor contains the AAG keyword of Door, Window, or 
Motion, but the sensor appears in the Property AAG when 
tripped, the name of the sensor is too long. The AAG keyword 
needs to be moved closer to the start of the sensor name. 

Summary of Contents for 60-924-3-C4TS5

Page 1: ...NINGS AND SAFETY INFORMATION WARNING Disconnect panel power before servicing CAUTION Use static electricity precautions when handling electronic components Installation guidelines The touch screen can be the primary interface to the panel or it can act as auxiliary interface working in conjunction with alphanumeric keypads such as Interlogix P N 600 1070 E or 60 983 The touch screen is not listed ...

Page 2: ...ktop stand at the removal tab marking until it separates Figure 1 with the other Figure 1 Desktop stand removal 2 Remove the touch screen from the mounting base pressing the opening button on the bottom of the touch screen as shown in Figure 2 In case the parts stick to each other try to separate them by inserting a small screwdriver into the opening slot beneath the protruding opening button Figu...

Page 3: ...uch screen into the lower part of the mounting base until you hear an audible click Note If necessary use a soft cloth to clear smudges on the touch screen Do not use glass cleaner Power up and bus communication Follow the steps below for powering up the panel and for verifying that the TouchScreen and other products like an alphanumeric keypad are properly communicating with each other Note On po...

Page 4: ...tion assignment With this menu assign bus devices to work in the desired partition To assign bus devices to partitions 1 With the display showing the desired bus device press 2 Press A or B until the display shows DEVICE PTN and then press The display shows PARTITION ASSIGN 3 Press 1 to 6 to select the desired partition The display flashes the entered selection 4 Press and the display shows the ne...

Page 5: ...Help menu which displays a list of help topic buttons Touch the buttons for information on a given topic Set Date Time Touch the related button to access the Date Time menu Code Required Access Touch the On or Off buttons to toggle this feature When turned on it will require a user access code to be entered for most touch screen functions With code required access not all icons will be displayed N...

Page 6: ...ral groups may result in a continuously red AAG motion icon Can both door and motion text be used in a sensor Not recommended Degraded or inhibited touch screen functionality Check wiring Confirm wire length is not exceeding 120 ft 22 gauge Re calibrate touch screen Problem Actions Solutions Trouble condition not displayed under status Refer to event buffer in touch screen and or view full status ...

Page 7: ...BILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS CONCORD 4 PRODUCTS AND RELATED SOFTWARE MANUFACTURER FURTHER DISCLAIMS ANY OTHER IMPLIED WARRANTY UNDER THE UNIFORM COMPUTER INFORMATION TRANSACTIONS ACT OR SIMILAR LAW AS ENACTED BY ANY STATE USA only SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIF...

Page 8: ...8 8 P N 466 5410 EN REV D ISS 19MAR18 ...

Reviews: