4.
Inspect and test all electrical connections, wiring and the different functions to make
sure that the electrical installation is complete.
To do so, you have to connect the
ground cable and control power connector again
.
5.
Make sure to install breather plug on the oil tank before running the unit, also
check the fluid level with the platform on the ground
.
+
-
+
-
+
-
Main power cable for liftgate is attached to + on main batt.
aux. batt. or trailer batt.
From the two wire harness blue is attached to + with a fuse
inline, brown is attached to -.
b
lu
e
brown
150 amp
breaker
To front plug on trailer
or main batt.
ground
Optional ground strap
attached to trailer
(ILUK only)
INTERLIFT POWER
HOOK UP.
Main Batteries, Aux. Batteries or Trailer Batteries
Liftgate mount frame