background image

The appliance uses LED lighting strips powered by a low voltage transformer. If 
replacement is required, please order genuine replacement parts from 

us

3

.

0

  

MAINTENANCE

3

.

1

  

Lighting

Please observe all of the safety warnings, precautions and instructions set out in Section 1.

The interior walls and shelves should be cleaned and sanitised on a regular basis so as 
to ensure hygiene regulations are met. Please do not use splashing, dripping, jetting 
or running water. Do not use steam. Only a damp or wet cloth should be used in 
conjunction with appropriate cleaning materials for the task in hand. Always follow the 

3

.

2

  

Cleaning the interior and exterior

The condenser is located at the front of the appliance behind the compressor compartment 
cover. The function of the condenser is to dissipate the heat that has been extracted

kept clean and free of dust at all times.

3

.

3

  

Cleaning the Condenser

This appliance has a low maintenance condenser that is less prone to blockage than 
other types. However it is still recommended to check that it is clean and dust free at 
least every three months. 

enclosure. Unplug from the mains power supply.

Step 2: Looking at the front of the appliance, remove the screws from the front

compartment cover.

Step 3: Locate the condenser and examine it for dust or debris.
Step 4: Clean the condenser using the nozzle of a vacuum cleaner or a soft brush.

Dust that is removed must be cleared away. The condenser is a delicate 

component and must be treated with great care and respect. Be careful of 

use water in this area.

Note: If the condenser has been contaminated with grease or fat, then a skilled and 
competent refrigeration specialist will be required to do the cleaning. Do not use the
cabinet or plug it back in until the cleaning has been done professionally by a skilled 

Step 5: Replace the cover and screws and plug back in to the mains power supply. 

7

Summary of Contents for PD110T

Page 1: ...rlevin PD110T PD220T Interlevin Refrigeration Ltd West Meadow Rise Castle Donington Derby DE74 2HL Sales 01332 850090 Parts 01332 850190 Service 01332 850064 Email trade sales interlevin co uk Web www...

Page 2: ...uctions carefully and keep the essential maintenance routines Failure to observe the instructions is unsafe and will also invalidate the guarantee booklet in a safe place for your future reference The...

Page 3: ...wer supply 4 5 1 3 Connecting the cooler to the Power Supply 6 2 0 OPERATION 2 1 Operation of the Appliance 6 2 2 Adjustment of the temperature 6 3 0 MAINTENANCE 3 1 Lighting 7 3 2 Cleaning the interi...

Page 4: ...ren without supervision Do not cover the front grille or rear air vents and please observe the installation and setting up instructions described later in this manual Adequate ventilation must be ensu...

Page 5: ...2 Unpacking and positioning before connecting to the power supply During all operations please be careful not to jolt jar bump or thump the cabinet Handle it gently and with care The refrigeration pip...

Page 6: ...sulted malfunctions may occur including but not limited to the condensate water not draining away and the doors not functioning correctly You may adjust the appliance using the The appliance requires...

Page 7: ...instructions The electronic controller has been factory set to chill the beverages to approximately 2 Centigrade Should you wish to alter the set point please adopt the following procedure 2 0 OPERAT...

Page 8: ...free of dust at all times 3 3 Cleaning the Condenser This appliance has a low maintenance condenser that is less prone to blockage than other types However it is still recommended to check that it is...

Page 9: ...F A MALFUNCTION inside wall of the refrigerated compartment It is often accompanied by or located next also within the insulation foam It must be recycled by a professional competent authorised and re...

Reviews: