inside this appliance.
Do not use any electrical appliances inside the refrigerated compartment of this appliance. 
Do not use any mechanical devices or other means to accelerate the defrosting process.
Defrosting is performed automatically by the electronic controller and needs no user
intervention.

the insulation foam. As such it is mandatory that the cabinet is serviced and, at

end-of-life, recycled by a professional organisation and skilled persons who have 

consult your Local Authority or contact 

us

.

The appliance uses LED lighting. The lighting strips and transformer should only be

During all operations, please be careful not to jolt, jar, bump or thump the cabinet. 
Handle it gently and with care. The refrigeration pipework is delicate and will be 

damaged by rough handling.

Do not exceed the maximum shelf loading weight of 25 kgs per shelf so as to avoid 
injury or damage.
Never move or tilt the appliance whilst the power switch is in the “ON” position.

Do not damage the refrigeration circuit. If you do so, then open a window or door

The appliance must always be earthed.

1

.

2

  

Unpacking and positioning (before connecting to the power supply)

During all operations, please be careful not to jolt, jar, bump or thump the cabinet. 
Handle it gently and with care. The refrigeration pipework is delicate and will be 
damaged by rough handling.
The appliance is heavy and therefore please carry out a risk assessment prior to 
beginning this operation.
Please cut the banding straps taking the necessary precautions to avoid hurting 
yourself or others. Remove all of the packaging and ensure that it is recycled in 

The appliance must only be charged with R600a refrigerant from an authorised supplier. 
To use another type of refrigerant would be dangerous and is not permitted under any 
circumstances.

Electrical equipment should not be placed under the unit or where refrigerant could 

gather in the event of a leak.
If it is necessary to repair the refrigeration such that it needs to be opened or charged,
then it will be necessary for the technician to possess a Gas Work Authorisation 

(hydrocarbon refrigerants). Queensland, Australia has particular regulations for such 

activities.

The electrical wiring diagram is to be found on the appliance itself and is located inside 

 
the cabinet on the side wall.

4

replaced using genuine parts of the same technical specification.

Summary of Contents for PD110T

Page 1: ...rlevin PD110T PD220T Interlevin Refrigeration Ltd West Meadow Rise Castle Donington Derby DE74 2HL Sales 01332 850090 Parts 01332 850190 Service 01332 850064 Email trade sales interlevin co uk Web www...

Page 2: ...uctions carefully and keep the essential maintenance routines Failure to observe the instructions is unsafe and will also invalidate the guarantee booklet in a safe place for your future reference The...

Page 3: ...wer supply 4 5 1 3 Connecting the cooler to the Power Supply 6 2 0 OPERATION 2 1 Operation of the Appliance 6 2 2 Adjustment of the temperature 6 3 0 MAINTENANCE 3 1 Lighting 7 3 2 Cleaning the interi...

Page 4: ...ren without supervision Do not cover the front grille or rear air vents and please observe the installation and setting up instructions described later in this manual Adequate ventilation must be ensu...

Page 5: ...2 Unpacking and positioning before connecting to the power supply During all operations please be careful not to jolt jar bump or thump the cabinet Handle it gently and with care The refrigeration pip...

Page 6: ...sulted malfunctions may occur including but not limited to the condensate water not draining away and the doors not functioning correctly You may adjust the appliance using the The appliance requires...

Page 7: ...instructions The electronic controller has been factory set to chill the beverages to approximately 2 Centigrade Should you wish to alter the set point please adopt the following procedure 2 0 OPERAT...

Page 8: ...free of dust at all times 3 3 Cleaning the Condenser This appliance has a low maintenance condenser that is less prone to blockage than other types However it is still recommended to check that it is...

Page 9: ...F A MALFUNCTION inside wall of the refrigerated compartment It is often accompanied by or located next also within the insulation foam It must be recycled by a professional competent authorised and re...

Reviews:

Related manuals for PD110T