Incorrect number of processors displays
Reason
Solution
Faulty CPU
Determine faulty CPU by swapping CPUs
until the faulty one is found.
CPU not properly seated into the socket.
Ensure all CPUs are properly installed.
Voltage Regulator Module (VRM) not
properly installed.
Ensure all VRMs are properly installed.
Incorrect amount of memory displays
Reason
Solution
Faulty SIMMs.
Determine faulty SIMMs by swapping
SIMMs until the faulty one is found.
SIMMs not properly seated into the socket.
Open the base unit and ensure SIMMs are
properly installed.
CD-ROM drive is not recognized
Reason
Solution
CD-ROM drive power cable not attached.
Open the base unit and ensure power cable
is properly attached.
CD-ROM drive SCSI cable not attached.
Open the base unit and ensure SCSI cable is
properly attached.
SCSI termination is not disabled.
Disable SCSI termination. Refer to the CD-
ROM drive vendor’s documentation.
A SCSI address conflict exists between the
CD-ROM drive and another SCSI device.
Set SCSI ID to an unused value. Refer to
the CD-ROM drive vendor’s
documentation.
I/O card parity error message displays
Reason
Solution
Faulty option board is installed in an ISA
slot.
Remove the ISA board, then restart the
server.
Riser card is faulty.
Call the Customer Response Center.