Interflex Datensysteme GmbH   

12/13 

 

This table applies to a controller with 8 possible terminals on bus 1: 

 

Old Address 

Old HA 

Controller 

Command 

Command 

New Address 

New HA 

Bus 

etp 8 -cx 

344161 

etp 8 -cx 

344262 

etp 8 -cx 

344363 

etp 8 -cx 

344565 

... 

etp 8 -cx 

... 

.. 

... 

... 

etp 1 -cx 

344868 

etp 9 -cx 

344262 

 

 

6.3  Bridges on the I/O controller board 

Check the setting of the bridges and adjust them, if necessary: 

 

Br. 1:

 When one I/O controller board is used, bridge 1 is always plugged in. 

  If a second I/O controller board is used, remove bridge 1 on the second I/O controller board.   

 

Br. 2

: Bridge 2 is used to set the switching contacts of the NO/NC relay. 

 

Br. 3

: Instead of bridge 3, an anti-tamper switch can be connected. 

See also 

Wiring Overview ........................................................................................................................ 8 

 

 

7  Initial Operation 

  Once you have connected the IF-80x Outdoor terminal and set the address, lock it using the mortise 

lock. 

  Additionally fasten the device with the included M2 x 6 mm countersunk head screw. 
  Switch on the power supply. 
  Configure the terminal in your host software, e.g. the IF-6040 system. 
  Make sure that your software recognizes and controls (online operation) the terminal. 
  Perform a booking at the terminal with a suitable credential. 
  Make sure that the booking reaches your host system where it is further processed. 

For further diagnosis purposes, special programs and tools are available to system engineers and 

consultants. 

 

Summary of Contents for IF-80x

Page 1: ...ocumentation are protected by commercial and patent laws 1 3 Shielded cables To ensure malfunction free operation we recommend the use of shielded bus cables Operation is also possible with unshielded...

Page 2: ...ices They are generally connected to a master terminal access manager or terminal controller via an RS485 data cable These terminals are designed for controlling the access of persons who identify the...

Page 3: ...appliance case 2 Alternative mounting hole for wall mounted cable inserted from the bottom 6 Mounting holes for US standard 3 Cable gland 7 Hole for adjusting the reader 4 Horizontal mounting option...

Page 4: ...ce Use only the original screws and do not use any washers Screws placed too high can cause collisions with other components and damage the device Ensure short cable routing Cable loops can damage the...

Page 5: ...ire is wrapped around the insulation 8 The blue wire and the PE wire from the I O controller board are connected to terminal 8 on the terminal strip 7 The blue wire is connected to the strain relief 9...

Page 6: ...rminal 3 Patch cable from computer to switch or hub 6 RS 485 data cable from controller master terminal to I O controller board Please refer to the table Function of Cables and Cable Types for detaile...

Page 7: ...e wire under a nut of the strain relief 12 Now connect all of the cables coming from the I O controller board to the terminal strip of the terminal Then connect the blue wire from the back panel of th...

Page 8: ...cuit example Power supply 7 Address switch on the I O controller board 4 Circuit example RS485 connection The spur line may not be longer than max 100 m Bridges Br 1 When one I O controller board is u...

Page 9: ...door terminal is usually very long we recommend connecting the power supply and the relay contact with one cable pair each 4 5 Connecting a further I O controller board If more than two inputs or more...

Page 10: ...maximum Setting the LEDs Use the DIP switch 4 to set the LEDs according to the color of the display The switch setting is usually preset factory default Check the setting of the DIP switches accordin...

Page 11: ...the terminal number Example cfg address 8 has been set Enter this command etp address cx The controller responds with TC ET 8 Then the command 34xxyy is sent directly to the terminal Example Address...

Page 12: ...board Br 2 Bridge 2 is used to set the switching contacts of the NO NC relay Br 3 Instead of bridge 3 an anti tamper switch can be connected See also Wiring Overview 8 7 Initial Operation Once you hav...

Page 13: ...condensing Protection category III Degree of protection IP54 provided that the cables are installed according to instructions The lower cable inlet must be masked using the included adhesive strip Dim...

Reviews: