Interflex IF-4076-0 Manual Download Page 1

IF-4076-0 
Access Manager

Controller

00-4076-04xx

Summary of Contents for IF-4076-0

Page 1: ...IF 4076 0 Access Manager Controller 00 4076 04xx...

Page 2: ...ess manager 12 4 Connecting the access manager 12 4 1 Cable routing 12 4 2 Wiring components 13 Ethernet network 13 Bus data cables with slave terminals 14 Floating status contacts and relays 15 4 3 C...

Page 3: ...ex Datensysteme GmbH IF 4076 0 Access Manager 3 6 Updating the software 26 7 Upgrading the controller 26 8 Technical specifications 27 8 1 General 27 8 2 IF 4070 27 9 Disposal 28 10 EU Declaration of...

Page 4: ...ng with integrated IF 4070 controller supporting plate for I O controller boards and power supply unit n Cable gland M20 x 15 n Strain relief plates with screw nuts n Split ferrite n Accessory bag wit...

Page 5: ...easures to ensure safe installation NOTICE Damage due to electrostatic discharge ESD Electrical components and modules can be damaged by only slight hardly noticeable electrostatic discharge ESD witho...

Page 6: ...ply unit if not pre installed NYM 3 x 1 5 mm2 Network cabling RJ45 patch cable preferably shield braiding 100 m From category 5 Cable to floating status contacts control cable 100 m J Y St Y 2 x 2 x 0...

Page 7: ...access n Access control including door control and monitoring n Storage of data required for offline operation e g credential numbers temporal and local permissions In offline mode the access manager...

Page 8: ...fuse 7 Transformer 8 Supporting plate for up to 16 I O controller boards The anti tamper switch 2 can be configured in such a way that it is monitored by the host system and triggers an alarm when th...

Page 9: ...1 Interflex Datensysteme GmbH IF 4076 0 Access Manager 9 Components 3 6 7 5 8 1 4 2 1 Host system 2 IF 4070 controller 3 Slave Terminal 4 Readers 5 Control element 6 Door opening push button 7 Door co...

Page 10: ...ttery for emergency power supply IF 4070 only 7 Screw terminal for the connection of the power supply 8 RJ45 socket for the connection to the Ethernet network host system 9 USB connection for future u...

Page 11: ...ng charged only for devices with optionally installed emergency power supply and switched on battery LINK Flashing Network data exchange SPEED On lights up off Network speed Lights up at 100 Mb off at...

Page 12: ...Connecting the access manager 4 1 Cable routing Observe the notes under Cable lengths and cable types 6 Recommended way to lay the cables to the housing n Power supply cable and protective earth Bott...

Page 13: ...edges with the enclosed grommets 2 3 Pierce a small hole in the grommet and feed the cable into the device 4 Secure all inserted cables using the shield connection terminals 4 5 Ground the cable shiel...

Page 14: ...s max Bus 3 6 slave terminals max Make sure that each slave terminal has a unique hardware address within the bus Data cables with slave terminals can be connected in two ways Connections on the print...

Page 15: ...ers or signal lamps up to 30V 2A NO or NC contacts can be used for switching An NO or an NC contact can be used for switching devices up to 30 V 2 A Outgoing cables can be looped at the PAT terminals...

Page 16: ...IN 7 11 IN 8 12 GND 14 GND 2 GND 4 GND 6 GND 8 GND 10 GND 12 GND Cable shield 10 Cable shield 13 or 14 Screw terminals for relays 800 801 802 Relay 1 Relay 2 Relay 3 Relay 4 Relay 5 Relay 6 Relay 7 Re...

Page 17: ...res Therefore please note the following u Use shielded cables Cable lengths and cable types 6 u Ground the shields on the devices and cables u Provide power to actuators e g door openers separately fr...

Page 18: ...3 n Via service interface or USB Service interface USB IF 4xxx controller 75 4070 0001 service cable 4xxx connection in housing IF 4070 controller 75 4070 0002 service cable 4xxx connection via RJ45 I...

Page 19: ...assword are the network services started and the network connection can be established 8 Establish network connection After the power supply has been switched on the device executes the following acti...

Page 20: ...nput syntax for commands n Commands are written in lowercase n Options are separated from the command by a blank and the minus sign n lists all possible command options n Press the Enter key to confir...

Page 21: ...tive 172 18 12 65 16 IPv4 gateway active 172 18 70 1 Port 2001 Hostname IF xxx fieldservice IF xxx The subnet mask is appended to the IP address as CIDR notation e g 172 18 70 23 16 CIDR notation Subn...

Page 22: ...terminals only Protocol terminalbus 0 erfProt 1 rsiProt 9600 8 noParity Your license allows 16 terminals as maximum Description base address Base address max 16 No of term bus n Number of terminals o...

Page 23: ...ware address with which the time access program manages slave terminals TNo Host management number The numbers are configured in the time recording access control program and are displayed after the d...

Page 24: ...A reboot performs the following actions n Close application n Shut down operating system n Boot operating system n Restart application 1 Set switches 2 Shortly press the Reset button 3 Wait until the...

Page 25: ...cation Reset network settings to factory default The network settings are reset 1 Set switches 2 Shortly press the Reset button The previous network settings are not saved temporarily unlike in earlie...

Page 26: ...at Here you will also find the system password 1 Open s_setpathvars bat in an editor and enter the system password 2 Adjust the paths for the programs pscp exe and plink exe if required for example if...

Page 27: ...0 m A 50 Hz or 115 VAC 10 420 m A 60 Hz Power consumption Max 50 VA General data Protection category I Degree of protection IP30 Dimensions H x W x D 604 x 304 x 105 Weight Approx 8 5 kg Housing mater...

Page 28: ...nstallation type Stackable desktop housing or installation in 19 rack Complete slide in module 1HE height unit 84 TE depth unit Nominal voltage 230 VAC 10 50 Hz 115 VAC 60 Hz optional Interfaces to ho...

Page 29: ...systeme GmbH does not assume any responsibility or liability for the accuracy of the information provided which is subject to change or updates without prior notice The original manual is in German Ot...