3 Trimming Procedure 

Trimming is a process of equalizing the output from multiple individual load cells. If 
needed, load cell output can be individually trimmed with potentiometers. 
Whenever a substantial amount of trim (more than 5% of normal output), seems 
necessary to equalize output check for other possible problems. The best trim is 
always the least amount of trim. When all errors except the cell mismatch and cable 
extensions or reductions have been corrected, continue with the trimming. 

 

3.1  Excitation Board Trimming Procedure 

Use the following steps to properly trim the JB104SS junction box. 

1.  Determine the number of load cells needed. 

2. 

Make sure jumpers have been removed to enable trimming of the desired cells 
corresponding to each load cell in use. 

See Figure 3 for the location of jumpers 

JP1, JP2, JP3 and JP4. Note that jumpers 

must 

be removed to enable trimming 

on the excitation board. 

3.  Set all potentiometers fully clockwise to give maximum signal output from each 

cell (see location of potentiometers below). 

 

Figure 7: Excitation Main Board 

Summary of Contents for JB104SS

Page 1: ...rement INTERFACE 7401 E Butherus Drive Scottsdale AZ 85260 PHONE 480 948 5555 FAX 480 948 1924 www interfaceforce com Email gen interfaceforce com ORDER TOLL FREE 1 800 947 5598 JunctionBox Rev B 05 2...

Page 2: ...convenient for servicing and away from standing water Try to mount the enclosure in a location so that the load cell cables need not be cut nor length added Load cell output is temperature compensated...

Page 3: ...mblies and leave the grips loose until final closure Before connecting load cell wires to the terminals strip the wire insulation back 1 4 to expose the wire The spring loaded terminals will accommoda...

Page 4: ...924 www interfaceforce com Email gen interfaceforce com ORDER TOLL FREE 1 800 947 5598 JunctionBox Rev B 05 21 18 Figure 3 Application Use JB104SS Wiring Load Cell Color EXC RED EXC BLK SIG GRN SIG WH...

Page 5: ...ment INTERFACE 7401 E Butherus Drive Scottsdale AZ 85260 PHONE 480 948 5555 FAX 480 948 1924 www interfaceforce com Email gen interfaceforce com ORDER TOLL FREE 1 800 947 5598 JunctionBox Rev B 05 21...

Page 6: ...ERFACE 7401 E Butherus Drive Scottsdale AZ 85260 PHONE 480 948 5555 FAX 480 948 1924 www interfaceforce com Email gen interfaceforce com ORDER TOLL FREE 1 800 947 5598 JunctionBox Rev B 05 21 18 Figur...

Page 7: ...roblems The best trim is always the least amount of trim When all errors except the cell mismatch and cable extensions or reductions have been corrected continue with the trimming 3 1 Excitation Board...

Page 8: ...er mechanical problems Select the load cell which has the lowest value as your reference point This cell will not be trimmed 6 Replace the same test load over each cell in turn Using the corresponding...

Reviews: