background image

Contents

Introduction 1
Safety  

1

Performance indexes 2
Product Description 

3

Structure 4
Menu Description 

5

Battery cover installation method 

6

Measurement 7
Focal distance 7
Elimination of noise 7
LED light 

7

Color palette 

8

Temperature of reflective background 

8

Marking of spot temperature 

8

Unit of temperature 

8

Image mixing 

9

Time Setting 

9

Image Capture and Storage 

10

Check internal storage 

10

Notes 10
Emissivity 11
Emissivity of normal materials 11
Maintenance 11

1. Introduction

HT-02 is a thermal Imaging Camera which combines the functions 

of surface temperature measurement and real-time thermal imaging.

  The traditional thermal Imaging Camera shall measure each 

component one by one but this instrument does not need to. 

Therefore, it helps to save our customers’ time. Even the potential 

problems can be clearly displayed on the color screen which helps 

customers quickly locate the central point to measure cursor and 

temperature.

  To improve recognition, this product is equipped with a vision 

camera. Based on practical requirements, it can turn thermal image 

into visional image. Thermal image and visional image can be 

stored in the dismountable memory card. Adjust the images and 

store them in PC which are used to generate report or for printing. 

HT-02 is easy to operate. After seconds it can be tested. This 

product is the optimum product for electrician and maintainer. It can 

quickly find out the problem area.

The following functions help to improve the accuracy and usability 

of product:

●  Adjustable radiation coefficient and reflection background  

  compensation help to improve the accuracy of the  

 

  measurement of semi-reflective surface.

●  The marking of hot spot and cold spot can help user to locate  

  the hottest and coldest area of thermal imaging temperature.

●  Options of color palette

2. Safety

To ensure the accuracy of measured results, please carefully read 

this manual before operation.

Please strictly follow this manual to operate our product. In case of 

any problems due to operational errors, the maintenance cost will 

be charged.

Do not use our product under the explosive or damp or corrosive 

atmosphere.

If our product is damaged, broken or has just been repaired, the 

measurement results might be inaccurate.

1

Summary of Contents for HT-02

Page 1: ...Thermal Imaging Camera Manual ...

Page 2: ... Based on practical requirements it can turn thermal image into visional image Thermal image and visional image can be stored in the dismountable memory card Adjust the images and store them in PC which are used to generate report or for printing HT 02 is easy to operate After seconds it can be tested This product is the optimum product for electrician and maintainer It can quickly find out the pr...

Page 3: ...age 60 60 3600 pixels Resolution of visible image 0 3 mega pixels Field angle shortest focal distance 20 20 0 5m Thermal sensitivity 0 15 C Range of temperature measurement 20 C to 300 C Accuracy of temperature measurement 2 or 2 C 2 or 4 Emissivity Adjustable 0 1 1 0 Image capturing frequency 6Hz Range of wave length 8 14um Focal distance Fixed focal distance Color palette Iron red rainbow rainbo...

Page 4: ... capturing key Interface for the installation of tripod 10 5 Structure 1 5 2 4 6 7 8 9 10 3 Figure 2 Structure of Product Description Time setting Save image Background light setting Temperature unit setting Background temperature setting Capacity of memory card Color palette setting Emissivity setting 6 Menu Description 12 12 5000 50 ºC 25ºC 11088MB 0 95 Icon Figure 3 Menu s Icons and Description...

Page 5: ...n Move the product until hot spot or cold spot coincides with the center of pixel Direct the product to the object whose temperature is higher or lower than the surrounding temperature to get the optimum measured results 9 Focal distance This product is the fixed focal thermal Imaging Camera The applicable distance is 50cm 20min Image storage 10 Elimination of noise Start up the instrument and the...

Page 6: ...y situations adjust the temperature of reflective background to get the optimum measured result 14 Marking of spot temperature Turn on or off the marking of spot temperature If turning on the marking of spot temperature indicates that the hot spot or cold spot in the screen needs additional appraisal If turning off it indicates that user can focus on the measured pixel per time 15 Unit of temperat...

Page 7: ...Press the MENU button to exit Review 20 Notes All the objects have the radiated infrared energy The radiated quantity of infrared energy is based on the actual temperature and radiation coefficient of surface Our instrument can sense the infrared energy on the surface of object and estimate the temperature based on the sensed value of infrared energy Many objects e g coated metal wood water skin a...

Reviews: