background image

12. Color palette

“Color palette” menu can change the fake color of the infrared 

image displayed on the screen or captured. A series of color palette 

is available for usage. Some color palettes are more applicable to 

the special areas, so they are set as required options. Gray-scale 

color palette provides balanced linear color, so it can help to fully 

reveal details. High-contrast color palette can emphasize the 

displayed color. This color palette is applicable to the hot-cold 

contrast situation. It is used to improve the color contrast of 

high-temperature and low-temperature. Iron red and rainbow color 

palettes provide a mixed high-contrast gray-scale color palette. 

13. Temperature of reflective background

The background temperature can be set between 0°C and +36°C.

Set the temperature compensation for reflective background in the 

option of background. Over-hot or over-cold object may influence 

the object or the surface temperature and measurement accuracy 

of measured object. When the radiation coefficient of the surface of 

the measured object is low, this phenomenon is obvious. Under 

many situations, adjust the temperature of reflective background to 

get the optimum measured result.

14.Marking of spot temperature

Turn on or off the marking of spot temperature. If turning on, the 

marking of spot temperature indicates that the hot spot or cold spot 

in the screen needs additional appraisal. If turning off, it indicates 

that user can focus on the measured pixel per time.

15.Unit of temperature

The product displays the temperature in unit of °C or °F.

16. Image mixing

Use the aligned visible image and infrared image. The mixed image 

makes the understanding of infrared image become easier. The 

product can capture the visible image of each infrared image to 

accurately display the temperature distribution of target area. It 

helps to share with others. If this mixing function is used, press “left” 

or “right” key to adjust the mixed image from 0% to 100%.

17. Time setting

In clock menu, use can set time and date. Press “menu” key to 

enter into “menu” mode. Press “up” or “down” key to select “clock” 

menu. Press “select” key to enter into the mode of clock calibration. 

Press “left” or “right” key to select the aimed time parameter. Press 

“up” or “down” key to add or subtract the value. After setting, press 

“menu” key to exit.

High contrast

Iron red

Rainbow

0%

30%

60%

80%

100%

14

4

11

12

26

Year  Month Day

Hour  Second

8

9

Summary of Contents for HT-02

Page 1: ...Thermal Imaging Camera Manual ...

Page 2: ... Based on practical requirements it can turn thermal image into visional image Thermal image and visional image can be stored in the dismountable memory card Adjust the images and store them in PC which are used to generate report or for printing HT 02 is easy to operate After seconds it can be tested This product is the optimum product for electrician and maintainer It can quickly find out the pr...

Page 3: ...age 60 60 3600 pixels Resolution of visible image 0 3 mega pixels Field angle shortest focal distance 20 20 0 5m Thermal sensitivity 0 15 C Range of temperature measurement 20 C to 300 C Accuracy of temperature measurement 2 or 2 C 2 or 4 Emissivity Adjustable 0 1 1 0 Image capturing frequency 6Hz Range of wave length 8 14um Focal distance Fixed focal distance Color palette Iron red rainbow rainbo...

Page 4: ... capturing key Interface for the installation of tripod 10 5 Structure 1 5 2 4 6 7 8 9 10 3 Figure 2 Structure of Product Description Time setting Save image Background light setting Temperature unit setting Background temperature setting Capacity of memory card Color palette setting Emissivity setting 6 Menu Description 12 12 5000 50 ºC 25ºC 11088MB 0 95 Icon Figure 3 Menu s Icons and Description...

Page 5: ...n Move the product until hot spot or cold spot coincides with the center of pixel Direct the product to the object whose temperature is higher or lower than the surrounding temperature to get the optimum measured results 9 Focal distance This product is the fixed focal thermal Imaging Camera The applicable distance is 50cm 20min Image storage 10 Elimination of noise Start up the instrument and the...

Page 6: ...y situations adjust the temperature of reflective background to get the optimum measured result 14 Marking of spot temperature Turn on or off the marking of spot temperature If turning on the marking of spot temperature indicates that the hot spot or cold spot in the screen needs additional appraisal If turning off it indicates that user can focus on the measured pixel per time 15 Unit of temperat...

Page 7: ...Press the MENU button to exit Review 20 Notes All the objects have the radiated infrared energy The radiated quantity of infrared energy is based on the actual temperature and radiation coefficient of surface Our instrument can sense the infrared energy on the surface of object and estimate the temperature based on the sensed value of infrared energy Many objects e g coated metal wood water skin a...