NOTE: THIS CHARGER IS PROTECTED
AGAINST REVERSE CONNECTION. CHARGING
WILL NOT COMMENCE IF BATTERY IS
INCORRECTLY CONNECTED.
3. Connect the charger to AC power supply.
NOTE: THE CHARGER WILL NOW SWITCH ON
AND THE YELLOW LED WILL LIGHT.
4. The charger will now commence to charge the
battery, as indicated by the RED charging LED's.
NOTE: The length of time the charger remains in
the "Charging Mode" depends on the size and state
of discharge of the battery. This is controlled by the
charger's solid state circuitry which constantly
monitors the state of the battery and provides the
correct charge automatically.
IMPORTANT: The charger should be allowed to go
through the complete charge routine in order to
obtain the optimum charge. This will take a
minimum of one hour.
5. When the GREEN "READY" LED comes ON, the
battery is ready for use.
NOTE: The battery may be connected to the
charger in the "READY" mode indefinitely, in order
to maintain the battery in a fully charged state while
not in use without risk of over charging.
IMPORTANT: The charger must be disconnected
from the power supply before disconnecting from
the battery to prevent the possibility of arcing.
6. During charging, the current flowing into the
battery is indicated by the LED Amp Meter. At the
start of charge, if the battery is normally discharged,
all 4 RED LED's will be on, and will go out in
sequence as the charge current drops. When the
last RED LED goes off, the internal proportional
timer will start, the GREEN LED will show
proportional to the time of the constant current time.
(T/2+1hr)
7. If the battery voltage is less than half a volt, the
battery is considered very heavily discharged. In
this case, the YELLOW charging LED will NOT
show.
This charger is suitable for use with all types of
lead acid batteries, including the new types of
Maintenance-Free and Gelled Electrolyte batteries.
1. Disconnect vehicle battery cables.
2. Connect charger to battery. Ensure correct
Polarity. BLACK lead to Negative (-) terminal and
RED lead to Positive (+) terminal.
NOTE: THE CHARGER IS PROTECTED
AGAINST REVERSE CONNECTION. CHARGING
WILL NOT COMMENCE IF THE BATTERY IS
INCORRECTLY CONNECTED.
3. Connect the charger to an A.C. Power Supply.
Check that the Red (Power) and Yellow (Charge)
indicator Led’s are On. After a time (Which
depends on how heavily the battery is discharged) ,
the yellow Led will begin to flash, indicating the
battery has reached 80% recharge level.
4. After a further time, the Green “Ready” Led will
indicate that the battery is fully charged. The
minimum time before the green “Ready” Led shows
is one hour. The battery should be left on charge
until required for use.
"LINEAGE and EX SERIES"
OPERATING INSTRUCTIONS
7