MODEL ICS 12/25A
   INPUT:  117 Volts AC 60Hz, 480 VA
   OUTPUT: 12 Volts DC,  25 Amps  

MODEL  ICS 24/25A 
   INPUT:  117 Volts AC 60Hz, 900 VA
   OUTPUT: 24 Volts DC,  25 Amps

MODEL ICS 36/20A
   INPUT: 117 Volts AC 60Hz, 1120 VA
   OUTPUT: 36 Volts DC,  20 Amps

MODEL ICS 48/20A
   INPUT: 117 Volts AC 60Hz, 1500 VA
   OUTPUT: 48 Volts DC,  20 Amps

Optional Export AC Input Ratings
100v-50Hz AC Input (Japan)
115/ 230v -50Hz AC Input (Europe) (CE)
Full Wave Phase Controlled Rectification
CONTROL:
Voltage limit:
Normal Mode 2.42 V/Cell
Gel-Cell Mode 2.33 V/Cell
Liquid Electrolyte Mode 2.62 V/Cell
Current limited to AMP rating MEAN DC.
Automatic timer starts when first stage voltage
limit reached. Proportional CV stage 
timer - t/2+1 hour.
Constant voltage 2.3 V/Cell after timeout, with 
Temperature Compenation.
PROTECTION:
Electronic reverse polarity. Short circuit shutdown
and current limit.
Combined Circuit Breaker and power switch on
front panel.
BATTERY TYPE & RATING (See Page 11 BTS)
ICS chargersare for use with Lead Acid Batteries of 
Minimum capacity 50 AH, Gel Cell, Absorbed 
Electrolyte or Liquid Electrolyte types by using the 
BTS (Battery Type Switch)

DIMENSIONS: (Inches) 
   12.0 " WIDE, 7.0" FRONT TO BACK, 7.0" HIGH

      

MODEL PS 12/5
   INPUT:  117 Volts AC 60Hz, 110 VA
   OUTPUT: 5 Amps DC   12 Volts

MODEL PS 12/10 
   INPUT:  117 Volts AC 60Hz, 220 VA
   OUTPUT: 10 Amps DC 12 Volts

MODEL PS 24/5
   INPUT: 117 Volts AC 60Hz, 200 VA
   OUTPUT: 5 Amps DC  24 Volts

MODEL PS 24/8
   INPUT: 117 Volts AC 60Hz, 320 VA
   OUTPUT: 8 Amps DC  24 Volts

Optional Export AC Input Ratings
100v-50Hz AC Input (Japan)
115/ 230v -50Hz AC Input (Europe)

Full Wave Phase Controlled Rectification

CONTROL:
Voltage limit:
Normal Mode 2.42 V/Cell
Gel-Cell Mode 2.33 V/Cell
Liquid Electrolyte Mode 2.62 V/Cell

Current limited to AMP rating MEAN DC.

Automatic timer starts when first stage voltage limit 
reached. Proportional CV stage timer - t/2+1 hour.

Constant voltage 2.3 V/Cell after timeout, with 
Temperature Compensation.
PROTECTION:
Electronic reverse polarity. Short circuit 
shutdown.
and current limit.
AC Input fuse in AC Input connector

BATTERY TYPE & RATING (See Page 11 BTS)
PS chargers are for use with Lead Acid Batteries, Gel 
Cell Absorbed Electrolyte or Liquid Electrolyte types by 
using the BTS (Battery Type Switch)

DIMENSIONS: (Inches)

6.5" WIDE, 6.0" FRONT TO BACK,  5.25" HIGH

PROFESSIONAL SERIES 

12 & 24 VOLT

SPECIFICATIONS

INDUSTRIAL/ COMMERCIAL SERIES

12,24,36,& 48 VOLT

SPECIFICATIONS

CONFORMS 

TO

U.L. 1236

2

Summary of Contents for Commercial Series

Page 1: ... Current Constant Voltage Proportionally timed system used in all Interacter models provides fast charging and optimal timing over a wide range of battery sizes and depths of discharge STANDARD FEATURES OF ALL INTERACTER CHARGERS LINEAGE SERIES LS MODELS are the most cost effective series and are available for 6 12 24 36 and 48 volt batteries rated at up to 6 amps EX SERIES EX Utilizes the LS cont...

Page 2: ...y Type Switch DIMENSIONS Inches 12 0 WIDE 7 0 FRONT TO BACK 7 0 HIGH MODEL PS 12 5 INPUT 117 Volts AC 60Hz 110 VA OUTPUT 5 Amps DC 12 Volts MODEL PS 12 10 INPUT 117 Volts AC 60Hz 220 VA OUTPUT 10 Amps DC 12 Volts MODEL PS 24 5 INPUT 117 Volts AC 60Hz 200 VA OUTPUT 5 Amps DC 24 Volts MODEL PS 24 8 INPUT 117 Volts AC 60Hz 320 VA OUTPUT 8 Amps DC 24 Volts Optional Export AC Input Ratings 100v 50Hz AC...

Page 3: ...sing the battery 3 CAUTION To reduce risk of injury charge only lead acid maintenance free or flooded lead acid type rechargable batteries Other types of batteries may burst causing personal injury and damage 4 Do not expose charger to rain or snow 5 Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire electric shock or injury to person 6 To...

Page 4: ...engine 1 Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery 2 Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes 3 Wear complete eye protection and clothing protection Avoid touching eyes while working near battery 4 If battery acid contacts skin or clothing wash immediately with soap a...

Page 5: ...nnect and disconnect DC output only after removing AC cord from electric outlet Never allow clips to touch each other 2 Attach clips to battery posts and twist or rock back and forth several times to make a good connection This tends to keep clips from slipping off terminals and helps to reduce risk of sparking FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR A BATTERY MAY CAUS...

Page 6: ...cian Improper connection can result in a risk of an electrical shock This battery charger is for use on a nominal 117 volt AC circuit and has a grounded plug that looks like the plug illustrated in sketch A A temporary adapter which looks like the adapter illustrated in sketches B C may be used to connect this plug to a two pole receptacle as shown in sketch B if a properly grounded outlet is not ...

Page 7: ...LED Amp Meter At the start of charge if the battery is normally discharged all 4 RED LED s will be on and will go out in sequence as the charge current drops When the last RED LED goes off the internal proportional timer will start the GREEN LED will show proportional to the time of the constant current time T 2 1hr 7 If the battery voltage is less than half a volt the battery is considered very h...

Page 8: ...attery posts to ensure good connection GREEN READY LIGHT DOES NOT APPEAR AFTER 18 HOURS 3 The Microprocessor Control can indicate a problem with the battery If the battery has not reached the First Stage of the Operation within 18 hours the charger may determine that a problem exists within the battery or the battery is too big for the charger s output rating The OVERRIDE TIMER FUNCTION is shown b...

Page 9: ...ccording to these instructions For service call or write the manufacturer CAUTION RISK OF ELECTRICAL SHOCK Do not attempt any servicing unless you are authorized and qualified to do so a CONSERVER CES INSTRUCTIONS CE MANUEL CONTIENT DES INSTRUCTIONS IMPORTANTES CONCERNANT LA SECURITE ET LE FONCTIONNEMENT b IL EST DANGEREUX DE TRAVAILLER A PROXIMITE D UNE BATTERIE AU PLOMB LES BATTERIES PRODUISENT ...

Page 10: ... LAS PINCES DU CORDON C C S ASSURER QUE LES PINCES NE SE TOUCHENT PAS l SUIVRE LES ETAPES SUIVANTES LORSQUE LA BATTERIE SE TROUVE DANS LE VEHICULE UNE ETINCELLE PRES DE LA BATTERIE POURAIT PROVOQUER L EXPLOSION DE CETTE DERNIERRE POUR REDUIRE LE RISQUE D ETINCELLE A PROXIMITE DE LA BATTERIE i PLACER LES CORDONS C A ET C C DE MANIERE A EVITER QU ILS SOIENT ENDOMMAGES PAR LE CAPOT UNE PORTIERE OU LE...

Page 11: ... For units fitted with wall mounting brackets the battery charger should be securely attached to an indoor dry vertical surface using four brass 8 X 1 round head wood screws not supplied The unit must be mounted vertically with the wires at the bottom in a location where airflow forcooling is unobstructed for six inches above and three inches to each side of the battery charger MODEL EX 2402 evalu...

Page 12: ...zed by the manufacturer accidents negligence or commercial use voids this warranty Parts subject to normal wear and tear are not covered by this warranty Should a unit be returned for a cause not covered by this warranty or without the items specified above any repairs handling or testing will be made at the owner s expense and risk ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY IMPLIED W...

Reviews: