![Inter-m DSA-2000Q Operation Manual Download Page 21](http://html1.mh-extra.com/html/inter-m/dsa-2000q/dsa-2000q_operation-manual_2075424021.webp)
ProfessIonAl PoWer AMPlIfIer
19
DsA-500Q/2000Q
5. 4 POLARITY SETTING
In PolArITY settings, you can set up each channel differently.
You can configure each channel to norMAl (normal phase) and InVerT (inverted phase), If you select
InVerT, the phase will be inverted 180°. Initially, all channels are set to norMAl.
5. 5 DELAY SETTING
In DelAY settings, you can set the DelAY value for each channel.
You can set values between 0.00 and 100.00msc in 48 steps for each channel. specifically, you can set the
value you want down to the second decimal point.
The initial value is set to 0.00msc.
If you set the DelAY value, the approximate value of the corresponding distance is displayed at the bottom
in MeTer units.
※
The DelAY range you can set in the In MenU is between 0.00 and 340.00msc.
5. 6 PRESET SETTING
PreseT settings offers load preset, save preset, and View Preset functions. Instructions for PreseT settings
are identical to the instructions for PreseT settings from the In MenU. for more detailed setting instructions,
please refer to section 4. 5 PreseT seTTInG on page 17 of this manual.
[ POLARITY ]
> CH1
NORMAL
CH2
NORMAL
CH3
NORMAL
CH4
NORMAL
O
: P
: 0.0d
: 40.0HZ
: 1.0
[ DELAY CH4 SET ]
000
.00msc
METER : 000 . 000000
O
: P
: 0.0d
: 40.0HZ
: 1.0
[ PRESET ]
> Load preset
Save preset
View preset
[ PRESET NAME SET]
DSA_500Q_001!
!
Summary of Contents for DSA-2000Q
Page 1: ...Operation Manual Professional Power Amplifier DSA 500Q 2000Q...
Page 31: ...ProfessIonAl PoWer AMPlIfIer 29 DsA 500Q 2000Q DIMENSIONS 25 420 38 482 88 440...
Page 33: ...noTe...
Page 34: ...noTe...
Page 35: ......