ProfessIonAl PoWer AMPlIfIer
16
DsA-500Q/2000Q
4. 3 DELAY SETTING
In DelAY settings, you can set the DelAY value for each channel.
You can set values between 0.00 and 340.00msc in 48 steps for each channel. specifically, you can set the
value you want down to the second decimal point. The initial value is set to 0.00msc.
If you set the DelAY value, the approximate value of the corresponding distance is displayed at the bottom
in MeTer units.
※
The DelAY range you can set in the oUT MenU is between 0.00 and 100.00msc.
4. 4 PEQ SETTING
In PeQ settings, you can set up each channel differently.
specifically, you can configure 8 BAnKs from BAnK 1 to 8 for each channel.
As for BAnK BYPAss, you can select between on and off. If BYPAss is set to on, the device does not
use the BAnK value that has been set. If BYPAss is set to off, the device uses the BAnK value that has
been set.
for TYPe, you can select between PeQ, Hsf, and lsf.
GAIn can be set between -15dB and +15dB in 0.1dB step increments. Please be aware that increasing
GAIn by too much may produce residual noise.
freQUenCY can be set between 20Hz and 20kHz in 0.1Hz step increments. The initial frequency setting
values are 40Hz, 100Hz, 200Hz, 400Hz, 1kHz, 2kHz, 4kHz, 10kHz.
When TYPe is configured to PeQ, Q fACTor can be set between 0.1 and 12.0 in 0.1 step increments.
When TYPe is configured to Hsf or lsf, it can be set between 0.1 and 1.0 in 0.1 step increments.
[ DELAY CH4 SET ]
000
. 00msc
METER : 000 . 000000
O
: P
: 0.0d
: 40.0HZ
: 1.0
HP
: 20.0HZ
: O
: 12d
[ PEQ ]
> CHANNEL 1
CHANNEL 2
CHANNEL 3
CHANNEL 4
[ EQ CH 1 ]
1
:2
> BANK 1
BANK 2
BANK 3
BANK 4
BANK 5
BANK 6
[ EQ CH 1 ] 1:
2
BANK 7
BANK 8
> ALL BYPASS : OFF
[ EQ CH B1 ]
> BANK BYPASS
: ON
TYPE : PEQ
GAIN : 0.0dB
FREQUENCY : 40.0HZ
Q FACTOR : 1.0
HP
: 20.0HZ
: O
: 12d