STEP TEN:

Connect the Water Supply System - CONT.

STEP ELEVEN:

Finishing Steps

•  Install protective caps on all exposed bolts.

•  Turn water supply on and check water flow.

•  Clean Slide and dispose of all debris caused by the installation.

HINT:

It is recommended that after several days of use, all visible bolted connections be 

re-tightened as needed.

FINAL INSPECTION / ANNUAL INSPECTION CHECK LIST:

1. Measure the depth and width of the water in front of the slide as well as the slide’s exit

height above water to ensure they conform to Diagrams A, B, and C on page 4.

2. Check the slide’s position on the deck and ensure it conforms to the diagrams on pages 5-6.
3. Ensure the slide is securely anchored to the deck and stable.
4. Inspect the runway for visible cracks or tears.
5. Inspect the runway and ensure a smooth, even sliding surface.  Ensure the gaskets

between the flanges are compressed uniformly.

6. Inspect the runway for any water leaks and adjust water flow for even water distribution

across sliding surface.  Ensure water does not splash outside the runway, and all water
running off the slide falls into the pool.

7. Inspect the slide for any loose or corroded fasteners.
8. Ensure there is a protective rubber cap on all exposed nuts and bolts.
9. Inspect all step-attachment points and ensure the steps are seated on the nylon support

rods correctly.

10. Inspect the ladder handrails for rigidity and attachment.  Can they be pulled out of their

sockets?

11. Inspect the slide for sharp edges or protrusions on the ladder, deck flanges, handrails

or runway.

12. Make sure the slide warning label is securely adhered to the slide.

NOTE:

this installation is not complete until you, the installer, gives the owner’s manual

to the customer and then reviews the intended use instructions with them.

Connect hose to female adapter.

Summary of Contents for X-STREAM SLIDE

Page 1: ...R N O N W A Y T U C S O N A Z 8 5 7 1 3 5 2 0 7 9 0 7 0 4 0 8 0 0 7 3 7 5 3 8 6 F A X 5 2 0 7 9 0 7 1 2 7 i n t e r f a b c o m X S T R E A M S L I D E Assembly Installation Instructions IMPORTANT THE...

Page 2: ...Entry Section 9 Step 3 Attach Handrails to Ladder Entry Section 9 11 Step 4 Attach Feet to Legs 12 Step 5 Assemble the Flume Sections 12 13 Step 6 Alignment of Flume Sections 13 Step 7 Attach Legs to...

Page 3: ...THE BOLTS AND ALL THREADS OR THE NUTS MAY SEIZE INTER FAB RECOMMENDS THAT A TWO PERSON CREW ASSEMBLE THE X STREAM SLIDE INTER FAB HIGHLY RECOMMENDS THAT YOU FOLLOW THE INSTALLATION SEQUENCE IN THIS MA...

Page 4: ...ivery system is on and lubricating the slide prior to use 15 Collision with another swimmer or a diver can result in serious injury or death for one or both persons Before sliding always make sure tha...

Page 5: ...s 4 6 from the back wall of the pool A minimum depth of four feet 4 must be maintained at a distance of nine feet 9 along the centerline of the slide from point A The above described water depth profi...

Page 6: ...N U A L X S T R E A M S L I D E 5 XS IM Rev 7 08 SBK XS INSTALL SLIDE PLACEMENT DIAGRAM FOOTPRINT DIAGRAM X Stream Slide Left Turn DIAGRAM D NOT TO SCALE DIAGRAM E NOT TO SCALE RECOMMENDED MIN DECK AR...

Page 7: ...U A L X S T R E A M S L I D E 6 XS IM Rev 7 08 SBK XS INSTALL SLIDE PLACEMENT DIAGRAM FOOTPRINT DIAGRAM X Stream Slide Right Turn DIAGRAM F NOT TO SCALE DIAGRAM G NOT TO SCALE RECOMMENDED MIN DECK AR...

Page 8: ...in that order For a Right Hand Slide C D is the upper flume and A B is the lower flume Flumes are labeled A B or C D in small letters centered on flanges A B Flume C D Flume Hardware Kits 5 Bottom Se...

Page 9: ...ides flume C D is the upper flume and A B is the lower STEP ONE Attach Ladder Foot to Ladder TIP The leg foot elephant foot for the ladder has a slant inside the other 2 feet do not slant The ladder f...

Page 10: ...lock washer over a 3 8 bolt then flat washer then push bolt through the pre drilled holes in the PVC ladder into the nuts embedded in the entry section leg receiver and tighten Fig 2 Ladder Step Suppo...

Page 11: ...thread 2 2 x5 16 all thread 3 2 1 2 x5 16 all thread Make sure to use provided anti seize on the all thread before inserting into the embedded nuts Insert handrail into the top section first as illus...

Page 12: ...fore attaching the flange nuts These two locations require a flat washer flange nut and rubber cap Hand tighten Make sure to use the provided lubricant on the all threads before attaching the flange n...

Page 13: ...lide use the cardboard box for protection Hand tighten the flume bolts for now they will be fully tightened once the flume is correctly aligned Right Turn or Left Turn Assembly The flumes are labeled...

Page 14: ...ns and the exit section are bolted together hand tight then gently push or pull on the flume sections to ensure a smooth even alignment of the sliding surface Next starting with the exit section tight...

Page 15: ...the entry section with the 4 holes in the Upper Flume Section and gently push them through Place a 3 8 flat washer then lock washer and then a 3 8 nut on each all thread Ensure a smooth even alignmen...

Page 16: ...it is not possible to drill the anchor bolt holes with the slide in place gently move the slide to one side allowing sufficient room to drill the anchor bolt holes Anchor bolts are in Hardware Kit XS...

Page 17: ...4 Inspect the runway for visible cracks or tears 5 Inspect the runway and ensure a smooth even sliding surface Ensure the gaskets between the flanges are compressed uniformly 6 Inspect the runway for...

Page 18: ...g material from entering the pool Wash with a mild soap such as hand dishwashing soap avoid using strong cleaners or abrasives Avoid strong alkaline such as tri sodium phosphate or highly acidic clean...

Page 19: ...xample side view of a slide foot and an wedge anchor used in a paver installation Pavers can be a maximum of 3 thick Pavers must be mechanically attached to the concrete pad using a setting material s...

Page 20: ...asher s s 8 H SS 3 8 X 3 TAP 3 8 x 3 hex head tap bolt s s 20 H 562 X 390 CAP gray protective cap XS 103 SS PVC LEG TO FLUME QTY PART NUMBER COMPONENT DESCRIPTION 12 H SS 3 8 16X2 3 8 x 2 hex head bol...

Page 21: ...I N S T A L L A T I O N M A N U A L X S T R E A M S L I D E 20 XS IM Rev 7 08 SBK XS INSTALL X STREAM SLIDE XS GR SS...

Page 22: ...X 310 CAP GRAY PROTECTIVE CAP 10 14 H 562 X 390 CAP GRAY PROTECTIVE CAP 11 20 12 12 15 H SS 3 8 F NUT 3 8 FINISH NUT S S 12 16 H SS 3 8 FLT WASHER 3 8 X 1 FLAT WASHER S S 22 20 12 17 H SS 3 8 LOC WASH...

Page 23: ...1 year from the date of retail purchase Unless expressly stated otherwise all products manufactured by Inter Fab are for residential installation and use only Inter Fab Inc expressly disclaims any and...

Reviews: