17
PS 9000 1U Series
PS 9000 1U Series • DC Laboratory Power Supply • User Manual
Figure 6 - Control Panel
Overview of the elements of the operating panel
For a detailed description see section
“1.9.4. The control panel (HMI)”.
(1)
Display
Used for indication of set values, menus, conditions, actual values and status.
(2)
Left hand rotary knob, with pushbutton function
Turn: adjusts various set values which are related to the DC output voltage.
Push: selects the decimal position of a value to be changed (cursor)
(3)
Button bank
Button
: Activates the setup menu for various device settings (see
„3.4.3. Configuration in the setup
menu“)
Button
: Navigates through menus, submenus and parameters (direction: up / left) or changes
view mode
Button
: Navigates through menus, submenus and parameters (direction: down / right) or changes
view mode
Button
: Submits altered parameters or set values in submenus, as well enters submenus. Can
also be
used to acknowledge alarms.
Button
: Cancels changes of parameters in the setup menu or leaves submenus
(4)
Right hand rotary knob, with pushbutton function
Turn: adjusts various set values which are related to the DC output current, the DC output power. Also
adjusts parameters in the setup menu.
Push: selects the decimal position of a value to be changed (cursor)
(5)
On/Off Button for DC output
Used to toggle the DC output between on and off, also used to acknowledge alarms. The LED indicates
the state of the DC output, no matter if the device is manually controlled or remotely (LED on = output on).
Summary of Contents for PS 9080-100 1U
Page 2: ......