InTemp CX500 Series Temperature Logger Manual
www.prosensor.com
•
Download & Stop. The logger will stop logging once the
download is complete.
A report of the download is generated and is also uploaded to
InTempConnect if you are logged in to the InTemp app with
your InTempConnect user creden
ti
als.
In the app, tap Se
ttin
gs to change the default report type
(Secure PDF or XLSX) and report sharing op
tions.
The report is
also available in in both formats for sharing at a later
ti
me. Tap
the Reports icon to access previously downloaded reports. See
www.intempconnect.com/help for details on working with
reports in both the InTemp app and InTempConnect.
Logger Events
The logger records the following events to track logger
operation
and status. These events are listed in reports
downloaded from the logger.
Event Name
Definition
Con
fi
gured
The logger was con
fi
gured by a user.
Connected
The logger was connected to the InTemp app.
Started
The logger started logging.
Stopped
The logger stopped logging.
Downloaded
The logger was downloaded.
Alarm Out of
Range/In Range
An alarm has occurred because the reading
was outside the alarm limits or back within
range.
Note:
Although the reading may return
to a normal range, the alarm indicator will not
clear in the InTemp app and the alarm LED will
continu
e to blink.
Safe Shutdown
The b
attery
level dropped below a safe
oper
atin
g voltage and performed a safe
shutdown.
Deploying the Logger
Use the m
ountin
g loop on the logger to secure it to a shipment
or other applica
tion
you are monitoring. You can also remove
the backing on the tape that is adhered to the top and bo
tt
om
of the logger to mount it
on a fla
t surface.
Protecting the Logger
Note:
Static electricity may cause the logger to stop logging.
The logger has been tested to 8 KV, but avoid electr
ostati
c
discharge by grounding yourself to protect the logger. For more
inform
ation,
search for “s
tatic
discharge” on onsetcomp.com.
Battery Information
The logger uses one CR2450 non-replaceable lithium b
attery
.
Battery
life for the CX502 is not guaranteed past the 1-year
logger shelf life.
Battery
life for the CX503 model is 1 year,
typical with a logging interval of 1 minute. Expected b
attery
life
for the CX503 varies based on the ambient temperature where
the logger is deployed and the frequency of connec
ti
ons,
downloads, and paging. Deployments in extremely cold or hot
temperatures or a logging interval faster than 1 minute can
impact battery l
i
fe. Estimate
s are not guaranteed due to
unce
rtainti
es in in
itial batte
ry condi
tion
s and opera
tin
g
environment.
WARNING:
Do not cut open, incinerate, heat above 85°C
(185°F), or recharge the lithium
battery
. The ba
tt
ery may
explode if the logger is exposed to extreme heat or condi
ti
ons
that could damage or destroy the b
attery
case. Do not dispose
of the logger or
batt
ery
in fi
re. Do not expose the contents of
the ba
ttery
to water. Dispose of
the battery according to local
re
gulations fo
r li
thium batt
eries.