Download & Stop. The logger will stop logging once the 

download is complete. 

A report of the download is generated and is also uploaded to 

InTempConnect if you are logged in to the InTemp app with 

your InTempConnect user creden

ti

als. 

In the app, tap Se

ttin

gs to change the default report type 

(Secure PDF or XLSX) and report sharing op

tions.

 The report is 

also available in in both formats for sharing at a later

 ti

me. Tap 

the Reports icon to access previously downloaded reports. See 

www.intempconnect.com/help for details on working with 

reports in both the InTemp app and InTempConnect. 

Logger Events 

The logger records the following events to track logger 

operation

 and status. These events are listed in reports 

downloaded from the logger. 

Event Name 

Definition 

Con

gured 

The logger was con

gured by a user. 

Connected 

The logger was connected to the InTemp app. 

Started 

The logger started logging. 

Stopped 

The logger stopped logging. 

Downloaded 

The logger was downloaded. 

Alarm Out of 

Range/In Range 

An alarm has occurred because the reading 

was outside the alarm limits or back within 

range. 

Note:

 Although the reading may return 

to a normal range, the alarm indicator will not 

clear in the InTemp app and the alarm LED will 

continu

e to blink.  

Safe Shutdown 

The b

attery

 level dropped below a safe 

oper

atin

g voltage and performed a safe 

shutdown. 

Deploying the Logger 

Use the m

ountin

g loop on the logger to secure it to a shipment 

or other applica

tion 

you are monitoring. You can also remove 

the backing on the tape that is adhered to the top and bo

tt

om 

of the logger to mount it

 on a fla

t surface. 

Protecting the Logger 

Note:

 

Static electricity may cause the logger to stop logging.

 

The logger has been tested to 8 KV, but avoid electr

ostati

discharge by grounding yourself to protect the logger. For more 

inform

ation, 

search for “s

tatic 

discharge” on onsetcomp.com. 

Battery Information 

The logger uses one CR2450 non-replaceable lithium b

attery

Battery

 life for the CX502 is not guaranteed past the 1-year 

logger shelf life. 

Battery

 life for the CX503 model is 1 year, 

typical with a logging interval of 1 minute. Expected b

attery

 life 

for the CX503 varies based on the ambient temperature where 

the logger is deployed and the frequency of connec

ti

ons, 

downloads, and paging. Deployments in extremely cold or hot 

temperatures or a logging interval faster than 1 minute can 

impact battery l

i

fe. Estimate

s are not guaranteed due to 

unce

rtainti

es in in

itial batte

ry condi

tion

s and opera

tin

environment. 

 

WARNING:

 Do not cut open, incinerate, heat above 85°C 

(185°F), or recharge the lithium 

battery

. The ba

tt

ery may 

explode if the logger is exposed to extreme heat or condi

ti

ons 

that could damage or destroy the b

attery

 case. Do not dispose 

of the logger or 

batt

ery

 in fi

re. Do not expose the contents of 

the ba

ttery

 to water. Dispose of 

the battery according to local 

re

gulations fo

r li

thium batt

eries.

 

Reviews: