Intellitec
131 Eisenhower Lane North
Lombard, IL 60148
630 268 0010 / 1 800 251 2408
P/N 53-00778-100 Rev. 062003
www.Intellitecsve.com
Intellitec
Application Installation and Trouble Shooting Guide
Mini-Bus Multiplex System
AUXILIARY OUTPUT MODULE
Part No. 00-00785-000
The Auxiliary Output Module is used when the system requires more than the four loads that can be switched by
the Master Module. The aux output module can switch up to three 10 Amp loads. It includes jumpers that
allow you to select the channel that will control each of the three outputs.
An additional Switch Module is
required to address this module. Two of these modules can be used with the additional switch panel set to “B”.
This allow up to six additional loads to be switched in addition to those on the master.
Any number of these outputs can be set to respond to the same switch, offering distributed switching ,
, or the outputs of two modules can be paralleled to provide more current for a
single load. (20-30Amps)
such as
left side/right side bank switching
SPECIFICATIONS
INSTALLATION
Be sure the wire feeding the module will safely carry the total current to be drawn from the module.
MAXIMUM CURRENT
Circuit Name
Fuse
Function
Channel
Conn
Fuse
Output 1
10 A
Switched
3 or 6
J2-2
F1
Output 2
10 A
Switched
4 or 7
J2-3
F2
Output 3
10 A
Switched1
5 or 8
J2-4
F3
Temperature:
-40 C to 85 C ambient
Operating Voltage:
10.0 - 16.5 VDC
Over Voltage Protection:
24 VDC for 1 minute
+150 V for 150 milliseconds
- 300 V
Select a location for the Auxiliary Module that will allow for easy replacement of the fuses for service and easy
connections to both the battery input and the loads. The location should also provide sufficient air space to
provide cooling for the module. Mount the module with four, #8 screws through the holes in the cover. Connect
the battery input lead to the Power stud.
Page 20