Intellitec
131 Eisenhower Lane North
Lombard, IL 60148
630 268 0010 / 1 800 251 2408
P/N 53-00778-100 Rev. 062003
www.Intellitecsve.com
Intellitec
Application Installation and Trouble Shooting Guide
Mini-Bus Multiplex System
CONNECTIONS
J1
Input
Mating Connector - AMP 1-480700-0
Mating Connector - AMP 1-480698-0
Mating Connector - AMP 640586-1
J1-1
+12 V Input (door power)
J1-2
IPX Signal
J1-3
Signal Ground
J2-1
Motor (+12 V for Close)
J3-1
Step-Well Light
J2
J3
Motor
Switches & Light
J2-2
Motor (+12 V for Open)
J3-2
Sensitive Edge Switch Gnd
J3-3
Sensitive Edge Switch
J3-4
Door Closed Switch Gnd
J3-5
Door Closed Switch
J3-6
Stand-Alone/Key Switch Gnd
J3-7
Stand-Alone/Key Switch
J1-3
J1-2
J1-1
J3-8
J3-7
J3-6
J3-5
J3-4
J3-3
J3-2
J3-1
J2-2
J2-1
MiniBus Multiplex
Door Controller
Made in the USA
By
Intellitec
P/N 00-00787-000
Com
Ground
Multiplex
Signal
12
V
olt
s
CLOSE
OPEN
S
tall
Current
Adjust
Power
Gnd
S
tand
alone/key
SW
S
tand
alone/key
Sw
Door
Closed
SW
Door
Closed
SW
Sen.
Edge
SW
Sen.
Edge
SW
S
tep-W
ell
Light
Door
B
Door
A
Jumper
Setting
Page 13
AMP Contacts
14-18 AWG
10-12 AWG
350919-3
640310.3
Jumper Settings
-
JP1
Door A 2-3
Door B 1-2