ELECTRONIC CLIMATE CONTROL

131 EISENHOWER LANE NORTH
LOMBARD, ILLINOIS 60148-5413
630-268-0010 / 1-800-251-2408

INTELLITEC

NEW SYSTEM PART NUMBERS

   Intellitec                 Fleetwood

  Part Description

   Part No.                    Part No.

Single Furnace Thermostat

00-00597-100              F80-0026

Dual Furnace Thermostat

00-00597-000              F80-0025

Control Module

00-00591-100              F97-0051

(11K/13.5K BTU air conditioner)
Control Module

00-00591-000               F97-0052

(11K/11K BTU air conditioner)
Current Sensor

01-00233-000               F93-2000

Temp Sensors (2)

00-00569-000               F93-2021

Temp Probe Cables (2)

11-00417-031               F07-9711

Change-Over

00-00331-000

F97-0060

Wiring Harness Kit

11-00375-000

F07-0150

Summary of Contents for ECC

Page 1: ...nt temperature When in the AUTO mode the unit automatically controls the compressors and selects the appropriate air conditioner fan speed based on the difference between the set point temperature and...

Page 2: ...GND There are two identical sets of controls on the panel one for each of the front and rear systems The potenti ometers allow the user to select a desired temperature for each system in the range of...

Page 3: ...cator will be lit when the associated function switch is in any mode except the OFF mode and the system has not shed the associated air conditioner compressor or fan The red SHED indicator will be lit...

Page 4: ...ected to pins 1 and 2 of connector J4 and the contacts for the rear furnace are connected to pins 4 and 5 of the same connector They are electrically isolated from all other circuitry on the Control M...

Page 5: ...GH FAN 12 VDC 1 VDC J3 4 YEL COMPRESSOR 12 VDC 1 VDC NOTE The PC2 and PC3 pigtail wire colors are included for reference only to identify the functions of the wires emanating from the Control Module T...

Page 6: ...n by all of the 120 VAC operated equipment in the coach being fed through the main panel The Current Sensor is mounted in the main panel and supplies an input signal to the Control Module When enough...

Page 7: ...WHT 2 2 CURRENT SENSOR GND WHT J1 PC1A FUNCTION COLOR pin pin 3 1 KEYED NOT CONNECTED 4 2 12 VDC POWER RED 5 3 KEYED NOT CONNECTED 6 4 POWER GROUND BLK 7 5 IPXGND BRN 8 6 IPX SIG YEL THE ECC CURRENT S...

Page 8: ...INTELLITEC USE OF THE ECC WITH AUXILIARY GENERATOR SETS USE WITH 4KW GENERATOR In systems using 4KW generator sets the main system includes a manual or automatic change over which selects the 30 Amp...

Page 9: ...ront system to the generator s second output to utilize generator s full output capability In this situation the ECC load shedding features will remain unchanged but the Current Sensor will not measur...

Page 10: ...connections to the ECC Thermostat If OK 1 Measure the DC voltage between the IPX SIG and IPX GND lugs and measure the voltage between pins 7 and 8 of J1 on the Control Module The voltage should read g...

Page 11: ...ck the continuity of the Comp Relay lead between the Control Module and the front A C unit B Slide the test switch on the Control Module towards J3 Rear compressor and high fan should turn on If not 1...

Page 12: ...d rear A C unit V ON indicator is on but the furnace does not operate in HEAT mode at any thermostat setting A Check the fuse or circuit breaker feeding the furnace B Move the set point control up to...

Page 13: ...e following situations 1 Shore power is plugged in 2 Generator is started and shore power is not plugged in 3 The 12 volt power to the control module is first applied 4 The Control Module has shed an...

Page 14: ...14 53 22130A100 131 EISENHOWER LANE NORTH LOMBARD ILLINOIS 60148 5413 630 268 0010 1 800 251 2408 ELECTRONIC CLIMATE CONTROL INTELLITEC...

Page 15: ...ingle Furnace Thermostat 00 00597 100 F80 0026 Dual Furnace Thermostat 00 00597 000 F80 0025 Control Module 00 00591 100 F97 0051 11K 13 5K BTU air conditioner Control Module 00 00591 000 F97 0052 11K...

Reviews: