background image

 

 

12

 

5.

 

Technical specifications 

                          Item 

                    ThermalTronix

 

TT-T2F-HTI

 

TT-G2F-HTI

 

Detector 

performance 

Type 

Un-cooled FPA detector 

Resolution 

160×120 

384x288 

Range of λ 

8

14μm 

Thermal sensitivity 

≤0.12

@30

 

Image 

performance 

Frame frequency 

50Hz 

LCD 

Colorful high resolution 3.5” LCD 

Lens parameters 

FOV 

30°×22.5°

 

40°x30.5° 

Spatial resolution 

3.3mrad 

2.18mrad 

Measurement 

analysis 

Measurement range 

-20

+600

 

Measurement calibration  Fixed emissivity 

Measurement mode 

Fixed spot measurement 

Number of palette 

black-hot,  white-hot,  fire-fighting,  rainbow, 

etc. 

pseudo 

color 

optional 

11 speudo color optional 

Safety 

performance 

Water resistance 

IP67 

Drop height 

1m 

Flame retardant class 

UL94-V0 

Power system 

Battery type 

Rechargeable NI-MH Battery 

Working time 

≥2 hours 

Charging time 

≤2 hours 

Rechargeable times 

≥500 

Environment 

parameter 

Long 

time 

working 

temperature 

-15

+50

 

Short 

time 

working 

temperature 

+50

+260

 

Storage temperature 

-40

+70

 

Physical 

characteristics 

Size 

190mm×128mm×273mm 

Weight 

≤1.3Kg 

Carry box 

Rubber 

 

Summary of Contents for ThermalTronix TT-T2F-HTI Series

Page 1: ...ThermalTronix TT G2F HTI TT T2F HTI Series Fire fighting Thermal Image Camera User Manual...

Page 2: ...e environment of darkness and smoke otherwise it may lead serious result Under the high temperature environment user must operate following the operating program otherwise it may damage the device or...

Page 3: ...ture environment battery life may be reduced a bit Under the dangerous environment when the battery capacity indicates low capacity alarm please escape at once Or the device may stop working resulting...

Page 4: ...started 3 3 1 Inserting battery 3 3 2 Remove battery 5 3 3 Notes on safety use battery 7 4 Operation guide 8 4 1 Interface description 8 4 2 Operation description 10 4 2 1 TT 2F HTI operation flow ch...

Page 5: ......

Page 6: ...ow visibility of smoke or darkness TT 2F HTI series adopt advanced un cooled FPA infrared detector and advanced real time infrared thermal image process circuit with high definition and sensitivity wh...

Page 7: ...ription Comment Power key Long press to power on off the camera Short press to change the color platter Battery slot buckle Knob battery slot Lens Germanium window LCD screen Note Practical device may...

Page 8: ...3 3 Getting started 3 1 Inserting battery Pull up the buckle of battery slot Open the cover of the battery slot Pull up the buckle of battery slot Open the cover of the battery slot...

Page 9: ...h down the buckle of the battery slot Note only standard accessory battery is allowed to use otherwise the battery may be stuck or wrong voltage will damage device Push the battery into the battery sl...

Page 10: ...5 3 2 Remove battery Pull up the buckle of battery slot Open the cover of the battery slot Pull up the buckle of battery slot Open the cover of the battery slot...

Page 11: ...battery from the battery slot Close the battery slot cover Push down the buckle of the battery slot Remove the battery from the battery slot Close the battery slot cover Push down the buckle of the b...

Page 12: ...below Environment temperature is 20 20 once every 6 months Environment temperature is 20 45 once every 3 months Environment temperature is 45 60 once every month Each time charging the electricity sh...

Page 13: ...e pseudo colorful palette There are four options rainbow black hot white hot and fire fighting 4 Spot temperature measurement crosshair Display the location of the current measured spot Note TT 2F HTI...

Page 14: ...ery symbol will flash wholly in order to warn the operator When working time of the battery is less than 2 minutes it will flash Battery exhausted in the middle of the screen After flashing 10 times t...

Page 15: ...im at the new target object Get the target thermal image Aim at the new target object Get the target thermal image Short press the power key Palette change Screen display Power off Long press power ke...

Page 16: ...mperature displayed on the top right corner Aim at the new target object Target temperature displayed on the top right corner Short press the power key Palette change Screen display Power off Long pre...

Page 17: ...ement calibration Fixed emissivity Measurement mode Fixed spot measurement Number of palette black hot white hot fire fighting rainbow etc 6 pseudo color optional 11 speudo color optional Safety perfo...

Page 18: ...install battery Battery is out of power Change battery Power off protection is enabled Wait for 5 seconds and reboot The camera power off automatically Battery is out of power Change battery Power off...

Reviews: