Applications: 

IT-3000-OCT représentative expert as follows: 

 

1. Up-Stream port 

IT-3000-OCT has one Up-Stream port, adopt 5 bit terminal block, be 

used to connect Up-Stream equipment like as Host PC. According to 

users  different  require,  You  can  choice  RS-232,  RS-485  or  RS-422 

mold to connect main equipment, the pin is defined in the products.   

2. Down-Stream port 

IT-3000-OCT has right Down-Stream port, adopt 5 bit terminal block, 

be  used  to  connect  Down-Stream  equipment  like  as  Pos  data 

collection  equipment.  According  to  users  different  require,  You  can 

choice  RS-485  or  RS-422  mode  to  connect  Down-Stream  main 

equipment. the pin is defined

 

in the products. 

 

Dimension: 

 

IT-3000-OCT FAQ: 

1. 

LED indicator instruction

 

1. 

PWR

 

Power supply indicator

Red 

2. 

UP

      Up-Stream port transfer data, LED Flash 

3. 

1-8

      Down-Stream port receive data, LED Flash 

2. LED indicator OFF 

   

1.  Power supply cable turnoff 

2.  Insert power supply failed   

3.  Choice incorrect Power supply 

3. Equipment examine automatic 

1.  When  interface  connectionless,  insert  the  power  supply,  PWR, 

UP indicator light, and Down-Stream port state indicator(1-8) light, 

the  quantity  of  the  lighting  LED  is  up  to  the  availability  of  the 

Down-Stream quantity. 

2.  If  the  t  is  RS-232,  Down-Stream  port  is  RS-422,  connect  the 

Up-Stream  port  to  PC  RS-232  port  correctly,  Using  “Start”→ 

“accessory” → “communication”, open the typical terminal, choice 

the  correct  COM  port  and  9600bps  speed,  shorting  the  down 

RS-422  port,  input  the  character  in  the  typical  terminal  window, 

you will see the data indicate. 

3.  Meanwhile, the Up-Stream TXD indicator correspond to   

Down-Stream  RXD  flash,  then  the  interface  communicate 

normally. 

Using  this  method,  you  can  test  all  the  Up-Stream  port 

correspond to Down-Stream port working normally or not. 

Note: 

The  Loop-back  testing  just  used  for  full-duplex 

communication, is not suitable for the RS-485 communication. 

4. Communication failure 

1. Use incorrect power supply 

2. Insert power supply failure 

3. The connection sequence incorrect 

4. Oppositive use up strem port and Down-Stream 

5. Down-Stream port connection incorrect 

6. Exceed the loading and transmit distance 

7. Using incorrect transfer media 

8. RS485/422 connection incorrect 

Packing List: 

IT-3000-OCT is shipped with following items. 

1. IT-3000-OCT

×

2. 220V power line

×

3. User manual 

×

 