Central Switching Module PTN-CSM310-A/PTN-CSM540-A                         Technical Support 

Release 03 05/2020

                                                                        

https://hirschmann-support.belden.eu.com

  

User Manual

 

Installation

 

Dragon PTN

 

Central Switching Module 

 

PTN-CSM310-A/PTN-CSM540-A

 

  

Содержание HIRSCHMANN Dragon PTN CSM310-A

Страница 1: ...l Switching Module PTN CSM310 A PTN CSM540 A Technical Support Release 03 05 2020 https hirschmann support belden eu com User Manual Installation Dragon PTN Central Switching Module PTN CSM310 A PTN CSM540 A ...

Страница 2: ... own use The performance features described here are binding only if they have been expressly agreed when the contract was made This document was produced by Hirschmann Automation and Control GmbH according to the best of the company s knowledge Hirschmann reserves the right to change the contents of this document without prior notice Hirschmann can give no guarantee in respect of the correctness ...

Страница 3: ...Clock Distribution Network Timing 15 2 2 6 Layer2 Link Aggregation LAG Link Aggregation Group on CSM310 A17 2 2 7 Self test 18 2 2 8 Alarming 18 2 2 9 Health Monitor 19 2 2 10 Hardware Edition 19 2 3 Onboard Interfaces 19 2 3 1 Heat Sink 20 2 3 2 Straps 21 2 3 3 DIP Switches 21 2 3 4 CSM Replacement Micro SD Memory Card 21 2 4 CSM Redundancy 22 2 4 1 General 22 2 4 2 Redundancy States 22 2 4 3 CSM...

Страница 4: ...e 8 CSM310 A Side View 19 Figure 9 CSM540 A Top View 20 Figure 10 CSM540 A Bottom View Including Micro SD Card 20 Figure 11 Micro SD Memory Card Interface 21 List of Tables Table 1 Differences CSM310 A CSM540 A 5 Table 2 Manual References 6 Table 3 LED Indications In Boot Operation 7 Table 4 LED Indications in Normal Operation 8 Table 5 Display Reboot Operation 9 Table 6 CSM Display Normal Operati...

Страница 5: ...0 A CSM540 A Digit1 3 in 310 refers to 3 series 5 in 540 refers to 5 series Digit2 and 3 10 in 310 refers to the ability to drive 10 Gbps ports 40 in 540 refers to the ability to drive 40 Gbps ports Nodes Types Use in aggregation nodes see Ref 3 in Table 2 Use in core nodes see Ref 3b in Table 2 Switching capacity Non blocking capacity for 4 x 1 Gbps 10 Gbps ports 24 x 1 Gbps ports Non blocking ca...

Страница 6: ...RM830 HiProvision Management Operation 2Eth DRA DRM831 Dragon PTN Ethernet Services 2Leg DRA DRM832 Dragon PTN Legacy Services 2Net DRA DRM833 Dragon PTN Network Operation 3 DRB DRM802 Dragon PTN Aggregation Nodes PTN2210 PTN2206 PTN1104 PTN2209 3b DRB DRM840 Dragon PTN Core Nodes PTN2215 4 DRA DRM810 Dragon PTN General Specifications 100 DRA DRM828 Dragon PTN Bandwidth Overview 2 MODULE DESCRIPTI...

Страница 7: ...dule currently is running After plugging in the module or rebooting it the module turns into the boot operation see Table 3 After the module has rebooted successfully the module turns into the normal operation see LEDs in Table 4 Table 3 LED Indications In Boot Operation Cycle PI PF FLT ACT LED 1 Slow blinking active CSM or standby passive CSM 2 Fast blinking 3 LED is lit LED is not lit The sub cy...

Страница 8: ...shed with a fine non conductive object e g a toothpick Push short Warm restart Single CSM Pushing the RESET button forces a warm start of the CSM without affecting the CSM configuration Redundant CSMs Pushing the RESET button on both CSMs simultaneously force a warm start without affecting the CSM configuration the CSM that was active before the reboot becomes the active one again after the reboot...

Страница 9: ...cription Normal re boot boot cycle Boot 1st step of the display reboot cycle Ld1 Ld2 Ld1t Ld2t 2nd step of the display reboot cycle The CSM can have two firmware loads active and spare load onboard that have been uploaded via HiProvision If load1 is active load2 is the spare load and vice versa This display cycle shows which firmware load is used to boot the CSM Ld1 Load1 is active and used by the...

Страница 10: ...SM switchover button the state is only briefly displayed IP IP Address This is the front IP address or the IP address of the HiProvision management port on the front panel which is in the range 172 16 0 1 172 20 100 209 This dedicated IP address depends on the node number and the slot in which the CSM has been plugged CSM 1 or CSM 2 If two redundant CSMs are plugged into the node both CSMs have an...

Страница 11: ...oken SD card Plug in the CSM again Redundant CSMs If the broken SD card is in the active CSM switch over first to make this CSM standby Pull out the standby CSM replace the SD card and plug in the CSM again In both cases above the new SD card will get a copy of the current CSM configuration after CSM insertion CSM x HW4 Processor error on CSM x x 1 or 2 Replace the CSM 2 3 4 CSM x HW5 Flash memory...

Страница 12: ...ugged in correctly and powered up If the problem persists replace PSU x PSU x OUTPUT PSU x output voltage missing x 1 or 2 PSU x TEMP PSU x temperature out of range x 1 or 2 POE x FAILURE PoE PSU x Power over Ethernet has not enough input voltage to deliver the normal PoE power x 1 or 2 Check the input voltage of the PoE PSU x S x IFM HWERR The module in slot S x has a hardware error Example S4 IF...

Страница 13: ...l 100 100Base T Signal 1000Base T 1 Transmit output DA 2 Transmit output DA 3 Receive input DB 4 DC 5 DC 6 Receive input DB 7 DD 8 DD Figure 3 HiProvision Management Connector Figure 4 Dragon PTN Management Both CSM Types Included Core Aggregation Dragon PTN MPLS TP Aggregation Network Dragon PTN MPLS TP Aggregation Network Dragon PTN MPLS TP Core Network Core Node HiProvision PC Dragon PTN Manage...

Страница 14: ...ified in the Entry Point s in the Discovery Tile in HiProvision Make sure that the CSM Front IP address of each node only belongs to its own unique subnet Therefor each node must be configured in a different subnet Redundant CSMs can be configured in the same subnet If they are configured in a different subnet make sure each subnet is unique network wide 2 2 Functional Operation 2 2 1 Exchange Dat...

Страница 15: ...k Distribution Network Timing The Dragon PTN network provides a number of mechanisms to perform synchronization clock distribution network timing The CSM makes sure that all the IFMs included in the node are synchronized See the table below for an overview of the mechanisms Table 9 Synchronization Clock Distribution Network Timing Overview Mechanism Domain What is synchronized Purpose SyncE Networ...

Страница 16: ...nodes to report the stability and accuracy of its distributed clock Circuit Emulation Services the best available clock must be assigned statically to a dedicated interface port NOTE The IFM manual indicates whether an IFM port can participate in SyncE NOTE The CSM management port does not participate in the SyncE clock distribution NOTE If no distributed clock is available in a node the node fall...

Страница 17: ...ation of multiple physical Ethernet links between a source and destination side into one combined logical Ethernet link A LAG is a combination of multiple Ethernet LAN ports within one logical port group maximum 8 ports per LAG and 8 LAGs per node The Link Aggregation is the communication between two LAGs E g one LAG in one Dragon PTN node and the second LAG in a third party switch application For...

Страница 18: ... etc 2 2 8 Alarming a Hardware Device Alarms The CSM supervises all the hardware in the node and generates the necessary device alarms when something goes wrong in the node These alarms are collected by HiProvision It can be configured in HiProvision via the Device Settings to output one or more of these alarms to the digital output contacts DO on the NSM in the node see also Ref 2Mgt 3 3b in Tabl...

Страница 19: ...r in HiProvision See also Ref 2Net in Table 2 This monitor shows more info on the CSM s usage in a node CPU usage Memory usage Disk Flash SD memory card usage 2 2 10 Hardware Edition The hardware edition of the CSM has been factory set and can not be changed It can be read out via HiProvision see Ref 2Mgt in Table 2 2 3 Onboard Interfaces Figure 8 CSM310 A Side View Micro SD Card Interface Extract...

Страница 20: ...ink is required for the natural cooling of the CSM module A heat sink can reach a high temperature during operation CAUTION Do not touch the heat sink when the CSM is in operation or when removing the CSM from the node It can be extremely hot Risk of getting burned Hidden Reset Button Heat Sink Display Management Connector Heat Sink Heat Sink Bottom Side Micro SD Card Interface ...

Страница 21: ...replacing CSM provided that both CSMs have the same firmware version and are used in the same node This SD card interface has an SD card plugged in by default Every time HiProvision loads a new or updated configuration into the node this SD card will be updated As a result this SD card always holds the latest node configuration Follow the steps below to replace a broken CSM with a new CSM Remove t...

Страница 22: ...n normal operation one CSM actively controls the backplane and IFMs whereas the other CSM is in standby mode Both CSMs have a dedicated heartbeat mechanism to control which CSM is active and which CSM is in standby mode 2 4 2 Redundancy States A CSM can be in three different redundancy states ACT Active STB Standby or PAS Passive The current state of each CSM can be viewed on the CSM display see 2...

Страница 23: ...Provision is connected to both CSMs each CSM having its own management cable whenever possible either directly or via a router switch If only one cable is available make sure that HiProvision is connected to the active CSM when performing load actions If the cable is connected to the standby CSM it is possible in HiProvision to make the standby CSM the active one and vice versa For more connection...

Страница 24: ...able 10 Other Specifications Description Value CSM310 A Weight 1 1 kg 2 4 lb MTBF 71 years at 25 C 77 F Power Consumption 27W measured at 25 C 77 F with data transport Module Size width 60 6 mm 2 39 inches height 126 mm 4 96 inches depth 195 mm 7 68 inches HiProvision Connection Via a twisted pair RJ45 connector for 10 100 Mbps BASE T Ethernet interface CSM540 A Weight 1 53 kg 3 36 lb MTBF 54 3 ye...

Страница 25: ...communication Union LAG Link Aggregation Group LED Light Emitting Diode LVD Low Voltage Directive MIB Management Information Base MPLS TP Multiprotocol Label Switching Transport Profile MTBF Mean Time Between Failures NSM Node Support Module OAM Operations Administration and Maintenance PF Power Failure PI Power Input PRC Primary Reference Clock PSU Power Supply Unit PTN Packet Transport Network P...