![IntelligentAg Recon Blockage Plus Operator'S Manual Download Page 10](http://html.mh-extra.com/html/intelligentag/recon-blockage-plus/recon-blockage-plus_operators-manual_2074131010.webp)
Recon Blockage Plus
™ Operator’s Guide
600890-000075, rev 1.0
Page 10 of 26
7. Configure
each ECU’s ports.
Figure 7: Configuration
– Port Configuration
NOTE:
If you connected your sensors in counterclockwise order instead of in clockwise
order, you do not need to re-arrange your runs here. Refer to Section 4 to change your
run direction.
a. Tap each ECU and verify that the run configuration in the app matches how your
runs are connected to the ECUs. If the
app doesn’t match your system setup:
•
Drag a run number to the correct port on the ECU diagram.
•
Toggle the switch next to a port number to disable or enable a port.
•
Tap
Reset
to revert the changes back to the original configuration.
•
Tap
Apply
to save the changes.
b. Tap the next arrow
.
8. Set up your work switch.
Figure 8: Configuration
– Work Switch Setup
a. Select if your implement is operating with section control.
b. Select the gateway serial number
next to “Which ECU has the work switch attached
to it”.