![Intelligent Weighing Technology Intell-Print OM7212 User'S Operation Manual Download Page 18](http://html1.mh-extra.com/html/intelligent-weighing-technology/intell-print-om7212/intell-print-om7212_users-operation-manual_2074100018.webp)
8 Communications Interfaces
The standard communications interface for the OM7212 printer is RS-232. The printer uses an RJ12 connector for this serial
interface.
8.1
RS232
8.1.1
Serial Interface Specifications
Data Transmission Method:
Asynchronous serial interface
Baud Rate:
User selectable
2400 to 115200
Word Format:
Start bit
1 bit
Data Length
7 or 8 bits
Parity
Odd, Even, None
Stop bit
1 bit
Signal Polarity:
MARK: Logic “1” (-10V) SPACE: Logic “0” (+10V)
Hardware Handshaking:
Mark: Data transmission not possible Space: Data transmission possible
8.1.2
RJ12 Connector Pin Assignment:
FUNCTION
PIN No.
INPUT-OUTPUT
F-GND
1
GND
TXD
2
OUT
RXD
3
IN
RTS
4
OUT
DSR
5
IN
DTR
6
OUT
8.2
Infrared (IR) Transmission
If your OM7212 is configured with the optional IR transceiver, it is capable of communicating via an IrDA 1.1 connection. To
determine if your printer is configured with an IR transceiver, print a test label as outlined in section 6 and look for the section
labeled “IR Port”.
8.2.1
Guidelines for IR Communication
Turn the printer on.
Place the host within 1 m (39 inches) of the printer’s IR port.
Make sure the host’s transmitter/receiver is within a 15 degree angle from the center axis of the printer lens. Please
refer to the drawing below: