17
Part 2: Interfacing and Configuring
Shield to Earth Ground
on Supply End Only
Ferrite Beads
*L
z
0.5 MH
* 0.5 MH is a typical starting point for the Common Mode Line Filters. By increasing or decreasing
the value of L you can set the drain current to a minimum to meet your application’s requirements.
Common Mode
Line Filters (2x)
From MicroLYNX
Shielded/Twisted Pair
Cable Length
as required
Motor
Connections
A
A
B
B
A
A
B
B
MForce
PowerDrive
Phase Outputs
Example B: Motor Cabling Greater Than 50 Feet
Figure 2.3.8: Motor Cableing Greater than 50 Feet
Recommended Motor Cable AWG Sizes
MForce PowerDrive Recommended Motor Cable AWG
1 Amperes (Peak)
5 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Length (Feet)
10
25
50*
75*
100*
Minimum AWG
20
20
18
18
16
Minimum AWG
16
16
14
12
12
2 Amperes (Peak)
6 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Length (Feet)
10
25
50*
75*
100*
Minimum AWG
20
18
16
14
14
Minimum AWG
14
14
14
12
12
3 Amperes (Peak)
7 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Length (Feet)
10
25
50*
75*
100*
Minimum AWG
18
16
14
12
12
Minimum AWG
12
12
12
12
12
4 Amperes (Peak)
*Use the alternative methods illustrated in example
B when cable length is ≥ 50 feet. Also, use the same
current rating when the alternate AC power is used.
Length (Feet)
10
25
50*
75* 100*
Minimum AWG
18
16
14
12
12
Table 2.3.1: Recommended Wire Gauges
Summary of Contents for MForce PowerDrive Plus MForce Series Microstepping PowerDrive
Page 1: ...Operating Instructions TM Excellence in Motion TM FORCE POWER DRIVE MICROSTEPPING...
Page 10: ...1 4 Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Page 18: ...1 12 Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Page 20: ...Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Page 24: ...Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Page 36: ...18 Microstepping MForce PowerDrive Manual Revision R040507...
Page 60: ...A 2 Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...