10
Microstepping MForce PowerDrive Manual Revision R040507
WARNING! DO
NOT
connect
or disconnect
power leads
when power is applied!
Disconnect the AC power
side to power down the
DC power supply.
Example C – Cabling 50 Feet or Greater, AC Power to Power Supply
Figure 2.2.4: AC To Full Wave Bridge Rectifier, Cabling over 50 Feet
Figure 2.2.5: AC Cabling - 50 Feet or Greater - AC To Power Supply
Shield to Earth Ground
on Supply End Only
P
Type RFI Filter
r
Required Current
Transformer - 10 to 28 VAC RMS for 48 VDC Systems
20 to 48 VAC RMS for 75 VDC Systems
Full Wave Bridge
+
-
Shielded Twisted Pair
Cable Length
as required
NOTE:
Connect the cable illustrated
in Figure 2.2.2 to the output of
the Full Wave Bridge
Example B: AC Power to Full Wave Bridge Cabling Over 50 Feet
Shield to Earth Ground
on Supply End Only
P
Type RFI Filter
r
Required Current
120 or 240 VAC
Dependent on
Power Supply
Power Supply
+
-
DC Volts Out
Shielded Twisted Pair
Cable Length
as required
NOTE:
Connect the cable illustrated
in Example A to the output of
the Power Supply
MForce PowerDrive Recommended Power Supply Cable AWG
1 Amperes (Peak)
3 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Length (Feet)
10
25
50*
75*
100*
Minimum AWG
20
20
18
18
16
Minimum AWG
18
16
14
12
12
2 Amperes (Peak)
4 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Length (Feet)
10
25
50*
75*
100*
Minimum AWG
20
18
16
14
14
Minimum AWG
18
16
14
12
12
*Use the alternative methods illustrated in examples B and C when cable length is ≥ 50 feet. Also, use the same
current rating when the alternate AC power is used.
Table 2.2.1: Recommended Wire Gauges
Summary of Contents for MForce PowerDrive Plus MForce Series Microstepping PowerDrive
Page 1: ...Operating Instructions TM Excellence in Motion TM FORCE POWER DRIVE MICROSTEPPING...
Page 10: ...1 4 Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Page 18: ...1 12 Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Page 20: ...Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Page 24: ...Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Page 36: ...18 Microstepping MForce PowerDrive Manual Revision R040507...
Page 60: ...A 2 Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...