Terminals and descriptions
:
•
1R
Power positive. +12V present when Outdoor Station calling or being
monitored.
•
2W
Power negative (GND)
•
3Y
Image signal (Video signal)
•
4B
Talk and control signal (Audio signal)
•
POWER TERMINAL: Black wire DC negative (-)
•
POWER TERMINAL: White wire DC positive (+)
It’s recommended you use shielded alarm cable 4x0.3mm
2
for distances up to
30m. For distances over 30m, we suggest you add coaxial cable (RG-59) to
connect the 3Y and 2W pin in addition to the alarm cable.
Note 1:
Plug the AC Adaptor in to the AC power terminal ensuring it is well seated.
Note 2: If you want to use multiple monitors:
For a single Monitor system, keep the
jumper (which is already on JP-VD ). If you are setting up a multi-Monitor
system, remove all JP-VD jumpers EXCEPT the last Monitor. NB If you are
setting up monitors PARALLEL rather than chained, the ‘last’ monitor is the
one physically furthest away from the door station.
Note 3:
JP-LK is used to enable the electric Lock function. Remove the jumper if you
are going to use the Monitor power to supply power to the Lock. Refer to the
Doorbell camera manual.
3. Standard System Connection
-2-