-3-
•
The rated power of the lock must be less than 12Vdc 300mA when using internal power
supply mode.
•
The GND must connect to the negative of the lock, and the COM connect to the positive .
•
The default unlock time is 3s. If different unlocking time is needed to be configured,
change the
Unlock Timing
on access keypad panel.
12V 300mA
+
-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Set Unlock Relay mode
to Normally Open(0)
A. Connection for Power-on-to-Unlock type:
12V 300mA
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
+
-
Set Unlock Relay mode
to Normally Closed(1)
B. Connection for Power-off-to-Unlock type:
4.2 External Power Supply Mode
When the electronic lock is over 12 Vdc, external power supply for the lock is needed.
•
The power supply for the lock must be less than 48Vdc 1.5A.
•
The default unlock time is 3s. If different unlocking time is needed to be configured,
change the
Unlock Timing
on access keypad panel.
+
+
-
-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Set Unlock Relay mode to
Normally Open(0)
Note: Cut off this line when
using external power supply
C. Connection for Power-to-Unlock type: