Page 18
3.
From the diagnostics menu, perform the wireless diagnostics by pressing
.
4.
The wireless diagnostics provides a visual indicator of the wireless signal
strength and associated IP address.
5.
Note signal strength; if non existent, replace USB wireless device.
6.
If IP address is 127.0.0.1, then software drivers are not loading
properly; reload current version of MC software.
7.
To exit the diagnostic, press
.
Sonar
1.
To begin, access the system menu by pressing the right arrow (as shown
by the red arrow).
2.
To access the diagnostics menu, press
(shown by red arrow).
3.
From the diagnostics menu, perform the sonar diagnostics by pressing
.
4.
From the Sonar diagnostics menu, exercise each sonar by placing an
object in front and observing value changes. Clean or replace sonar if not
changing value .
5.
From the diagnostics menu, perform the sonar diagnostics by pressing
.
Summary of Contents for HydroBot Series