INT-44HDX
Installation Guide
23
Advanced Front Panel and IR Remote Operation
EDID Management
To copy the EDID from output 3 to input 1:
1.
Press EDID.
2. Press input 1.
3. Press output 3.
4.
Press ENTER.
To copy the EDID from output 3 to all inputs:
1.
Press EDID.
2.
Press ALL.
3. Press output 3.
4.
Press ENTER.
The INT-44HDX has five built-in EDID settings for the inputs, but also allows copying the EDID information of an
output device to the input of the matrix.
Copy EDID from Output to Input
To enable one of the built-in presets:
1.
Press and hold EDID for 3 seconds.
2. Press the input number to change.
3.
Press output 1 or output 2 to cycle through the built-in EDID tables.
4.
Press ENTER to confirm the changes.
There are five types of built-in EDID data. The chart below illustrates the settings of the built-in EDID data.
Copy EDID from Output to Input
No. EDID Data
1
1080P 2D 2CH (default)
2
1080P 3D 2CH
3
1080P 2D Multichannel
4
1080P 3D Multichannel
5