INT-44HDX
Installation Guide
11
Installation Instructions
Quick Start
Mount the Matrix
Shelf Mounting Instructions
Rack Mounting Instructions
1.
Mount the matrix
2.
Connect ground (optional)
3.
Connect sources
4.
Connect displays
5.
Connect audio (optional)
6.
Connect control (optional)
7.
Apply power
At least two inches of free air space is required on both sides of the INT-44HDX for proper side ventilation. Avoid
mounting the INT-44HDX near a power amplifier or any other source of significant heat.
Attach the supplied shelf feet to the bottom of the INT-44HDX matrix.
Attach the supplied rack ears to the sides of the INT-44HDX matrix with the supplied screws. The matrix requires
one rack unit (1 RU) of space. It is recommended that you leave an empty rack space above and below the
INT-44HDX for additional cooling.
Connect Ground
A ground screw is located on the bottom right rear of the matrix to help eliminate static shock during installation
of the matrix. Connect a wire from the matrix to an earth ground.
HDBaseT Cabling Requirements
For all HDBaseT cabling, the EIA/TIA-568B crimp pattern must be used on Category 5e or greater cable. In
areas with large amounts of electromagnetic (EM) or radio frequency (RF) interference, a shielded variety of
Category 5e or greater cable is recommended with shielded connectors on both ends of the selected cable.
TIA/EIA-568B
Orange/White
Orange
Green/White
Blue
Blue/White
Green
Brown/White
Brown
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
1
8
The HDBaseT ports provide 15 watts of Power over Ethernet to 48 volt based HDBaseT devices, which eliminates
the need for a power supply with a compatible HDBaseT device. All Intelix branded HDBaseT receivers that
accept remote power are compatible with the INT-44HDX.