FLX-44 Installation Guide
23
HDCP Commands
Description
Command
Response
Turn HDCP Compliance off for input
xx
/%I/xx:0.
/%I/xx:0.<CR><LF>
Turn HDCP Compliance on for input
xx
/%I/xx:1.
/%I/xx:1.<CR><LF>
Example:
/%I/04:0.
Turn HDCP Compliance off for input 4
RS232 Routing
RS232 strings to control remote devices can be passed through the main RS232 or TCP/IP port. This is a
bidirectional communication method. Maximum string length is 48 bytes (characters).
In addition to immediate transmission, the FLX-44 can store commands to be broadcast when the matrix
is powered on or off through the standby commands (PWON. and PWOFF.).
<Y> is the output code
<B> is the baud rate
<$> is the RS232 string
Command:
/+<Y>/<B>:<$>.
Output
Code
Timing
1
1
Immediate TX
A
PWON command
Baud
Baud
Code
E
PWOFF command
2400
1
2
2
Immediate TX
4800
2
B
PWON command
9600
3
F
PWOFF command
19200
4
3
3
Immediate TX
38400
5
C
PWON command
57600
6
G
PWOFF command
115200
7
4
4
Immediate TX
D
PWON command
H
PWOFF command
ALL
5
Immediate TX
Example:
/+C/4:PowerOn.
When the matrix is powered on, send the string
PowerOn
to output 3 at 19200 baud
Summary of Contents for FLX-44
Page 26: ...FLX 44 Installation Guide 26 ...
Page 27: ...FLX 44 Installation Guide 27 ...