Intelix REM-PACK-8
Installation Manual
12 www.intelix.com
7)
Connect the CW-TB to the ION-LT with an IR (1/8” stereo mini)
cable.
4)
Determine which twisted pair cable is connected to the CB-1000
remote controls. It is imperative you determine which conductors
are terminated to the remote control. In most twisted pair cables,
these conductors will be color-coded. Using the cable:
i.
Connect the (+) power conductor on the CB-1000
remote to the (+) power conductor on the CW-TB.
ii.
Connect the (-) power conductor on the CB-1000
remote to the (-) power conductor on the CW-TB.
iii.
Connect the (+) IR conductor on the CB-1000 remote
to the (+) IR conductor on the CW-TB.
iv.
Connect the (-) IR conductor on the CB-1000 remote
to the (-) IR conductor on the CW-TB.
Your system should now be fully connected: the CB-1000 remote
controls should be connected to the CW-TB, the CW-TB should be
connected to the ION-LT, and the ION-LT should be connected to
the controlled hardware.
Note
Only four CB-1000 units may be connected to one CW-TB when
powering the remotes over the twisted pair cable. Therefore,
additional groups of remotes must be connected to subsequent
CW-TBs. Multiple CW-TBs may be daisy-chained using twisted
pair cable.