10
In figure 1 of the example above we have the area we want to protect. Figures 5 and 6 indicate that the trimpot
adjustment exceeded the limits of the environment to be protected. In this way the microwave will detect move-
ments outside the desired area.
To make it easier to adjust the microwave cover, adjust the trimpot counterclockwise (less sensitive) and walk in
the room you want to protect. Observe the sensor motion detection. If necessary, increase the sensitivity (clockwi-
se). Repeat this process until the sensor only protects the environment where it is installed.
The figure below shows a microwave channel detection range reference.
Factory default:
50%
Microwave range
Trimpot position
Maximum distance
0% up to 1 meter
25% up to 5 meters
50% up to 12 meters
75% up to 15 meters
100% up to 18 meters
4.2. Operating mode settings
The key (S1) allows you to configure the sensor’s operating mode:
Key 1 – LED:
works in conjunction with the LED input to control the visual indication of motion detection.
LED
Key 1
LED input
LEDs
Condition
Result
ON
12 Volts
LEDs on
OFF
0 Volts
LEDs on
ON
0 Volts
LEDs off
OFF
12 Volts
LEDs off
Factory default:
LEDs on.