5. Operation

When turning on the sensor, the blue LED flashes for approximately 60 seconds. This time is necessary for the stabilization 
of the circuits that make up the sensor. After this period, if they are enabled, the LEDs light up with each motion detection.
The LEDs have automatic intensity adjustment according to the brightness of the installed environment.

 

»

Blue LED: 

alarm

 

»

Yellow LED: 

Pir

 

»

red LED: 

microwave

5.1.  Remote self test

With this function it is possible to remotely enable or disable the visual indication of the LEDs and thus
remotely perform a test run of the product.
For this, it is necessary to combine the adjustment of the LED switch with the voltage applied to the LED input 
of the product.
For more details on the functioning adjustment, see item 

4.2. Operating mode settings

5.2.  Self sabotage

For each of the attempts to tamper with the sensor, the red LED flashes quickly and the PROBLEM output acts to indicate 
the type of tampering.
It is highly recommended that the TROUBLE output be connected to a zone of the control panel with 24-hour function 
enabled.

Sensor output indication table

Exit

Cause

Solution

Alarm

Problem

Open and restore

Closed

Trigger (PIR and Microwave)

or anti-camouflage

Check the conditions of the installed environment and make the best 

microwave setting.

Open

Open

Masking

Check sensor lens for obstruction.

Closed

Open

Low supply voltage level

Check if the sensor supply voltage is greater than 9 V.

Closed

Open and restore

Position change

Check if the sensor has changed its installation position or if it is not 

properly fixed.

Summary of Contents for IVP 9000 MW MASK

Page 1: ...User manual IVP 9000 MW MASK...

Page 2: ...ses the efficiency of motion detection and reduces undetected areas below the sensor The IVP 9000 MW MASK sensor also contains technologies for anti cloaking anti masking detection of light sources mo...

Page 3: ...animals weighing up to 10 kg If the animal is on top of a bench for example the PET function can be overridden When installing the sensor in environments with the presence of animals it is recommende...

Page 4: ...Detection area Top view Detection angle Side view 2 1 m 0 1 3 6 9 12 15 18 m Side view 0 1 3 6 9 12 15 18 m 2 1 m...

Page 5: ...t 7 4 Installation 8 4 1 Microwave sensitivity adjustment 9 4 2 Operating mode settings 10 4 3 End of line resistor settings 12 4 4 Process completion 16 5 Operation 17 5 1 Remote self test 17 5 2 Sel...

Page 6: ...MW Blue Alarm Startup time 60 seconds Relay opening time 3 seconds Operating Temperature 10 C to 50 C Recommended installation height 2 1 meters Dimensions W H D 67 134 54 mm Weight 134 g 2 Features A...

Page 7: ...screw 6 Wire passage seals 7 Seals for wall installation 8 Seals for corner installation 9 Connector 10 External base 11 Internal base Board 12 Pyro sensor 13 Microwave module 14 LEDs 15 Connector 16...

Page 8: ...installation location to avoid changes in the product s detection angle Incorrect use of the articulator can change the sensor s de tection area creating blind spots and impairing operating efficienc...

Page 9: ...ut the XSA 1000 articula tor consult the user manual on the website www intelbras com br The recommended screw for attaching articulators to the product is 3 5 9 5 mm XSA 1000 Position 1 Position 2 Mo...

Page 10: ...ockwi se Repeat this process until the sensor only protects the environment where it is installed The figure below shows a microwave channel detection range reference Factory default 50 Microwave rang...

Page 11: ...vity This setting is suitable for semi open environments or environments with some interference that could cause unwanted triggering With the key in the OFF position the sensitivity remains with autom...

Page 12: ...is enabled With the key in the OFF position anti tamper remains disabled Antissabotagem Position Condition ON Enabled OFF Disabled 4 3 End of line resistor settings The IVP 9000 MW MASK has 3 sets of...

Page 13: ...rol panel does not have a compatible configuration keep all switches in the OFF position Possible adjustments of the IVP 9000 MW MASK sensor with Intelbras alarm center 0 Single zone without end of li...

Page 14: ...ction ALARM ALARM TAMPER PROBLEM ZONE 1 ZONE 2 ZONE 3 3 Single zone with end of line resistor tamper detection and wiring short circuit ZONE 1 ZONE 2 ZONE 3 ALARM ALARM TAMPER PROBLEM 4 Dual zone with...

Page 15: ...ine resistor tamper detection and wiring short circuit Connection with an IVP 9000 MW MASK sensor using the Alarm and Trouble output ALARM ALARM TAMPER PROBLEM ZONE 1 ZONE 2 ZONE 3 Connection with two...

Page 16: ...ing short circuit detection ALARM ALARM ALARM ALARM TAMPER TAMPER PROBLEM PROBLEM ZONE 1 ZONE 2 ZONE 3 4 4 Process completion Once the sensor is configured close it by sliding up the front case on the...

Page 17: ...ED input of the product For more details on the functioning adjustment see item 4 2 Operating mode settings 5 2 Self sabotage For each of the attempts to tamper with the sensor the red LED flashes qui...

Page 18: ...ion change This function consists of monitoring undue changes in the sensor installation angle ensuring that it does not become unusable if its installation position is changed Upon detecting a change...

Page 19: ...sensor is able to detect your movements during the journey through the LEDs Adjust the microwave s sensitivity to the size of the room or reposition the sensor Be sure to take all precautions and fol...

Page 20: ...ct is not one of manu facture but is caused by the Consumer or by third parties foreign to the manufacturer b if the damage to the product arises from accidents disasters agents of nature lightning fl...

Page 21: ...via e mail suporte intelbras com br Customer Service 0800 7042767 Where to buy Who installs it 0800 7245115 Produced by Intelbras S A Ind stria de Telecomunica o Eletr nica Brasileira Rodovia BR 459 k...

Reviews: