Page 2: ...ntelbras quality and safety The IVP 3011 Cortina sensor is suitable for doors and windows pro tection It can detect with angle of 15 through passive infrared rays allowing effective detection and redu...

Page 3: ...ansversal movements in relation to the sensor de tection beams when entering in to the environment The suggested installation height is 2 2m Do not put objects that can block scan in front of the sens...

Page 4: ...Detection range side view 6 m 4 m 2 m 2 2 m Side view 0 m Terminal block Tamper Anti tamper key GND negative source 12 V Positive source Alarm Sensor output Alarm Tamper GND 12...

Page 5: ...Summary 1 Technical specifications 6 2 Producto 6 3 Features 7 4 Installation 7 5 Operation 10 6 Test 12 Term of Warranty 13...

Page 6: ...PIR Detection distance 6m Alarm output NC NA 500 mA 100 Vdc Recommended installation height 2 2 m Startup time 60s Detection angle 15 Anti tamper key TAMPER NC Size 80 35 30 mm LED ON OFF Detection pu...

Page 7: ...justable infrared sensitiveness PIR Optional NC and NO relay output 4 Installation Execute the installation in an area free of obstacles that may hinder the visual field of the sensor The PIR P COUNT...

Page 8: ...all without bracket 1 Tear the base of the plastic bag to pass the bolts as indicated Fig 3 2 Attach the sensor passing the screw through the holes in the back cover Fig 4 Note M3X25 self drilling scr...

Page 9: ...g 5 2 Fit the sensor into the bracket Fig 6 3 To remove the sensor from the bracket just use a small driver as a lever in the lock on the left side Fig 7 Note M3X25 self drilling screws Figure 5 Figur...

Page 10: ...ximum sensitivity one pulse pins 1 2 With the jumper in the 2P position the sensor provides intermediary sensitiveness two pulses pins 2 3 and in this position the sensor provides proper detection for...

Page 11: ...D Jumper P COUNT Position Condition 1 P 1 Pulse maximum sensitivity 2 P 2 Pulse minimum sensitivity Jumper relay Position Condition NC Normally closed NO Normally open Jumper LED Position Condition ON...

Page 12: ...vements to sensor detection by observing the LED indication Note while a movement could be detected the LED remains on and will indicate open or closed Walk through the area where you want to protect...

Page 13: ...ailure due to improper use the Customer shall bear any of these incurred expenses 2 The product must be installed according to the Product Manual and or Installation Guide If your product requires to...

Page 14: ...software and applications up to date and if necessary the required network protections against intrusions hackers The equipment is warranted against defects under normal conditions of use and it is im...

Page 15: ...te tecnico Support via e mail suporte intelbras com br Customer Service 0800 7042767 Where to buy Who installs it 0800 7245115 Imported to Brazil by Intelbras S A Ind stria de Telecomunica o Eletr nic...