Thermal Specifications
90
Intel® Xeon® Processor 3500 Series Datasheet Volume 1
To protect platforms from potential operational or safety issues due to an abnormal
condition on PECI, the Host controller should take action to protect the system from
possible damaging states. If the Host controller cannot complete a valid PECI
transactions of GetTemp0() with a given PECI device over 3 consecutive failed
transactions or a one second max specified interval, then it should take appropriate
actions to protect the corresponding device and/or other system components from
overheating. The host controller may also implement an alert to software in the event
of a critical or continuous fault condition.
6.3.2.4
PECI GetTemp0() Error Code Support
The error codes supported for the processor GetTemp() command are listed in
.
6.4
Storage Conditions Specifications
Environmental storage condition limits define the temperature and relative humidity
limits to which the device is exposed to while being stored. The specified storage
conditions are for component level prior to board attach (see following notes on post
board attach limits).
specifies absolute maximum and minimum storage temperature limits which
represent the maximum or minimum device condition beyond which damage, latent or
otherwise, may occur. The table also specifies sustained storage temperature, relative
humidity, and time-duration limits. At conditions outside sustained limits, but within
absolute maximum and minimum ratings, quality & reliability may be affected.
Notes:
1.
Refers to a component device that is not assembled in a board or socket that is not to be electrically
connected to a voltage reference or I/O signals.
2.
Specified temperatures are based on data collected. Exceptions for surface mount reflow are specified in by
applicable JEDEC standard and MAS document. Non-adherence may affect processor reliability.
3.
T
ABSOLUTE
STORAGE
applies to the unassembled component only and does not apply to the shipping media,
moisture barrier bags or desiccant.
4.
Intel® branded board products are certified to meet the following temperature and humidity limits that are
given as an example only (Non-Operating Temperature Limit: -40°C to 70°C & Humidity: 50% to 90%,
non-condensing with a maximum wet bulb of 28°C) Post board attach storage temperature limits are not
specified for non-Intel® branded boards.
Table 6-5.
GetTemp0() Error Codes
Error Code
Description
8000h
General sensor error
Table 6-6.
Storage Condition Ratings
Symbol
Parameter
Min
Max
Notes
T
abs storage
The non-operating device storage
temperature beyond which damage (latent
or otherwise) may occur when subjected
to for any length of time.
-55 °C
125 °C
1, 2, 3
T
sustained storage
The ambient storage temperature limit (in
shipping media) for a sustained period of
time.
-5 °C
40 °C
4, 5
RH
sustained storage
The maximum device storage relative
humidity for a sustained period of time
60% @ 24°C
60% @ 24°C
5,6
Time
sustained storage
A prolonged or extended period of time;
typically associated with customer shelf
life.
0 months
6 months
6
Summary of Contents for Xeon 3500 Series
Page 1: ...Document Number 321332 002 Intel Xeon Processor 3500 Series Datasheet Volume 1 July 2009 ...
Page 8: ...8 Intel Xeon Processor 3500 Series Datasheet Volume 1 ...
Page 12: ...Introduction 12 Intel Xeon Processor 3500 Series Datasheet Volume 1 ...
Page 92: ...Thermal Specifications 92 Intel Xeon Processor 3500 Series Datasheet Volume 1 ...
Page 98: ...Features 98 Intel Xeon Processor 3500 Series Datasheet Volume 1 ...