![Intel SRCSASLS4I - RAID Controller Hardware User'S Manual Download Page 9](http://html1.mh-extra.com/html/intel/srcsasls4i-raid-controller/srcsasls4i-raid-controller_hardware-users-manual_2071959009.webp)
Intel® RAID Controller SRCSASLS4I Hardware User’s Guide
3
•
Advanced Array configuration and Management Utilities provides:
—
Online Capacity Expansion (OCE) adds space to existing drive or new drive.
See Appendix A for limitations on OCE and RAID migration.
—
Online RAID level migration (upgrade of RAID mode, may require OCE).
—
Drive migration.
—
Drive roaming.
—
No reboot necessary after expansion.
•
Upgradeable Flash ROM interface.
•
Allows for staggered spin up, hot-plug, and lower power consumption.
•
User specified rebuild rate (percent of system resources to use from 0-100%).
Caution: Exceeding 50% rate may cause operating system errors due to waiting for
controller access.
•
Background operating mode can be set for Rebuilds, Consistency Checks,
Initialization (auto restarting Consistency Check on redundant volumes); Migration,
OCE, and Patrol Read.
Redundancy and Error Handling
•
In-band and out-of-band SES2.
•
Enclosure management support.
•
Fault indicators per drive.
•
Drive coercion (auto-resizing to match existing disks).
•
Auto-detection of failed drives with transparent rebuild. There must be disk activity
(I/O to the drive) for a missing drive to be marked as failed.
•
Auto-resume on reboot of initialization or rebuild (must be enabled before virtual
disk creation).
•
Smart initialization automatically checks consistency of virtual disks if there are five
or more disks in a RAID 5 array, which optimizes performance by enabling read-
modify-write mode. RAID 5 arrays of only three or four drives use Peer Read mode.
•
Dirty cache LED plus error reporting for cache write to disk.
•
Smart Technology predicts failures of drives and electronic components.
•
Patrol Read checks drives and maps bad sectors.
•
Commands are retried at least four times.
•
Firmware provides best effort to recognize an error and recover if possible.
•
Failures are logged from controller and drive firmware, and SMART monitor.
•
Failures are logged in NVRAM, viewable from OS Event Log, Intel
®
RAID Web
Console 2; CIM, LEDs, and via alarm.
Summary of Contents for SRCSASLS4I - RAID Controller
Page 1: ...Intel RAID Controller SRCSASLS4I Hardware User s Guide Intel Order Number E33167 002...
Page 4: ...iv Intel RAID Controller SRCSASLS4I Hardware User s Guide...
Page 6: ...vi Intel RAID Controller SRCSASLS4I Hardware User s Guide...
Page 12: ...6 Intel RAID Controller SRCSASLS4I Hardware User s Guide...