SAI2 Server Board TPS
Basic Input Output System (BIOS)
Revision 1.0
43
Code
Error Message
Failure Description
0B61:
DIMM #2 has been disabled
Memory error, memory group #2 failed
0B62:
DIMM #3 has been disabled
Memory error, memory group #3 failed
0B63:
DIMM #4 has been disabled
Memory error, memory group #4 failed
0B6F:
DIMM with error is enabled
An error detected in all the memory
0B70:
The error occurred during temperature sensor reading
Error while detecting a temperature failure.
0B71:
System temperature out of the range
Temperature error detected.
0B74:
The error occurred during voltage sensor reading
Error while detecting voltage
0B75:
System voltage out of the range
System voltage error
0B7C:
The error occurred during redundant power module
confirmation
The error occurred while retrieving the power
information
0BB0:
SMBIOS – SROM data read error
SROM data read error
0BB1:
SMBIOS – SROM data checksum bad
Bad checksum of SROM data
0BD0:
1st SMBus device address not acknowledged.
Some SMBus device (chip) failed
0BD1:
1st SMBus device Error detected.
0BD2:
1st SMBus timeout.
N/A
Expansion ROM not initialized.
PCI Expansion ROM card not initialized
N/A
Invalid System Configuration Data
System configuration data destroyed
N/A
System Configuration Data Read Error
System configuration data read error
N/A
Resource Conflict
PCI card resource is not mapped correctly.
N/A
System Configuration Data Write error
System configuration data write error
N/A
Warning: IRQ not configured
PCI interrupt is not configured correctly.
8503:
Incorrect memory speed in location: XX, XX, …
Non-PC133 DIMMs have been installed in slots
XX, XX, …
A beep code is a series of individual beeps on the PC speaker, each of equal length. The
following table describes the error conditions associated with each beep code and the
corresponding POST checkpoint code as seen by a port 80h card. For example, if an error
occurs at checkpoint 22h, a beep code of 1-3-1-1 is generated.
Table 31. POST Error Conditions and Beep Codes
Beeps
Error
Cause
Recommended Action
1-2-2-3
ROM Checksum Error
—
Change system board
1-3-1-1
DRAM Refresh Test Error
—
Change memory DIMM's
1-3-1-3
Keyboard Controller Test Error
—
Change system board
1-3-3-1
Memory Not Detected
No memory.
Can not write to memory
Verify DIMM installation.
Change memory DIMM's
Memory Capacity Check Error
No memory.
Can not write to memory
Verify DIMM installation.
Change memory DIMM's
1-3-4-1
DRAM Address Test Error
Memory address signal failure
Change DIMM or M/B
1-3-4-3
DRAM Test low byte Error
Memory data signal failure (low)
Change DIMM or M/B
1-4-1-1
DRAM Test high byte Error
Memory data signal failure (high)
Change DIMM or M/B
1-4-3-3
All Memory Group Errors
—
—
2-1-2-3
BIOS ROM Copy-Write Test Error Error with Shadow RAM
Change system board
2-2-3-1
Unexpected Interrupt Test Error
Unexpected interrupt
Change CPU or system board