Intel® Server Board S1200SP Family Technical Product Specification
44
Feature
Basic*
Advanced**
Hot-Swap Fan Support
Yes
Yes
Acoustic Management
Yes
Yes
Diagnostic Beep Code Support
Yes
Yes
Power State Retention
Yes
Yes
ARP/DHCP Support
Yes
Yes
PECI Thermal Management Support
Yes
Yes
E-mail Alerting
Yes
Yes
Embedded Web Server
Yes
Yes
SSH Support
Yes
Yes
Integrated KVM
Yes
Integrated Remote Media Redirection
Yes
Lightweight Directory Access Protocol (LDAP)
Yes
Yes
Intel
®
Intelligent Power Node Manager
Support***
Yes
Yes
SMASH CLP
Yes
Yes
* Basic management features provided by Integrated BMC
**Advanced management features available with optional Intel
®
Remote Management Module 4
*** Intel
®
Intelligent Power Node Manager Support requires PMBus*-compliant power supply
6.3
Advanced Configuration and Power Interface (ACPI)
The server board supports the following ACPI states.
Table 13. ACPI Power States
State
Supported
Description
S0
Yes
Working
The front panel power LED is on (not controlled by the BMC).
The fans spin at the normal speed, as determined by sensor inputs.
Front panel buttons work normally.
S1
No
Not supported
S2
No
Not supported
S3
No
Supported only on Workstation platforms. See appropriate Platform Specific
Information for more information.
S4
No
Not supported
S5
Yes
Soft off
The front panel buttons are not locked.
The fans are stopped.
The power-up process goes through the normal boot process.
The power, reset, front panel NMI, and ID buttons are unlocked.