5. Connect power cords to the server units and the JBOD enclosure and power the units.
Cabling Configurations
This section contains information about initially setting up a Intel
®
RAID High Availability Storage
configuration with one or two JBODs. It also explains how to add a second JBOD to a single-JBOD
configuration without interrupting service on the configuration.
The following figure shows how to set up a two-controller-node configuration with a single JBOD
enclosure.
Figure 8 Two-Controller-Node Configuration with Single JBOD
The cross-connections between the controllers provide redundant paths that safeguard against ESM
failure.
To retain consistent device reporting, the corresponding port numbers for both controllers must be
connected to a common enclosure ESM. In this example, port 0 to port 3 of both controllers are connected
to ESM A and port 4 to port 7 of both controllers are connected to ESM B.
The following figure shows how to set up a two-controller-node configuration with two JBOD enclosures.